Publish your products
MACH 370, 450
Ferroli

MACH 370, 450

High power condensing generator with wide modulation range for outdoor installation. Max output power in heating mode (50/30°C) 371 kW NOx class 6° Modulation range (Pmin/Pmax) 1/25 Max operated pressure 6 bar
Specification
  • High-power condensing boiler, with high modulation range up to 1/40. Designed for installations both in technical rooms and outdoors without protection. Thermal group composed of a cascade of aluminium-silicon alloy elements designed for maximum efficiency and minimum pressure drops on the hydraulic circuit. Each unit is completed by the circulation group and the pre-mix combustion group. Total pre-mixing group, for micro-flame combustion with very low polluting emissions (class 6 in compliance with EN 15502-1). The metallic microfibre burner can run on natural gas or LPG Generator protection systems: * Double probe system (flow and return) to operate at constant ΔT (from 0 to 60°C) * Flue gas safety sensor * Water pressure switch with a minimum limit of 0.8 bar * Hydraulic unit with 3-way shut-off valve for discharge into the atmosphere and non-return valve on flow Air/Flue gas circuit with suction on the installation site and flue gas non-return clapet valve integrated on the suction group in order to size the flue gas manifold under pressure Control panel protected by a door integrated into the casing Four sturdy floating wheels installed as standard to facilitate unloading and mobility during installation. Adjustable feet for positioning. Designed to be installed both indoors and outdoors even without any protection from atmospheric agents (up to a temperature of -5°C). It can be connected to the system either on the right or on the left and it is delivered complete with blind flanges. In combination with THETA+ thermoregulation, it is possible to install more MACH generators in series (up to 8 units) * The MACH electronic control can manage a system with two direct zones and a DHW storage tank or more complex systems at different temperatures in combination with THETA+ thermoregulation. RANGE RATED certified generator to adapt the power generated to the needs of the system, to increase the efficiency of the system while preserving the mechanics of the machine from continuous switching on and off. The modules can be controlled and operated remotely: Power or temperature regulation with 0 - 10V signal Blocking alarm signal for safety and restoration of operation ModBus communication protocols (in combination with THETA+ thermoregulation)
Technical specification
  • Unique ref.MACH370450
  • Product familyHVAC - Boilers
  • Product groupBoilers
  • TypeObject (single object)
  • Date of publishing2022-05-12
  • Edition number1
  • Height (mm)1550
  • Width (mm)1630
  • Depth (mm)710
Related
  • Material mainMetal
  • Material secondaryPlastic
  • Designed inItaly
  • Manufactured inItaly
  • Weight Net (Kg)360
Classification
  • BIMobject CategoryHVAC - Boilers
  • IFC classificationBoiler
  • OmniClass Number23-33 11 13
  • OmniClass TitleCondensing Boilers

Region availability

Europe Asia North America Africa South America Oceania
Åland Islands
Afghanistan
Anguilla
Algeria
Argentina
American Samoa
Albania
Armenia
Antigua and Barbuda
Angola
Bolivia
Australia
Andorra
Azerbaijan
Aruba
Benin
Brazil
Cook Islands
Austria
Bahrain
Barbados
Botswana
Chile
Federated States of Micronesia
Belarus
Bangladesh
Belize
Burkina Faso
Colombia
Fiji
Belgium
Bhutan
Bermuda
Burundi
Ecuador
French Polynesia
Bosnia and Herzegovina
British Indian Ocean Territory
British Virgin Islands
Cameroon
Falkland Islands (Islas Malvinas)
Guam
Bulgaria
Brunei
Canada
Cape Verde
French Guiana
Kiribati
Croatia
Cambodia
Caribbean Netherlands
Central African Republic
Guyana
Marshall Islands
Cyprus
China
Cayman Islands
Chad
Paraguay
Nauru
Czech Republic
Christmas Island
Collectivity of Saint Martin
Comoros
Peru
New Caledonia
Denmark
Cocos (Keeling) Islands
Costa Rica
Côte d'Ivoire
Suriname
New Zealand
Estonia
Georgia
Cuba
Democratic Republic of the Congo
Uruguay
Niue
Faroe Islands
Hong Kong
Curaçao
Djibouti
Venezuela
Norfolk Island
Finland
India
Dominica
Egypt
Northern Mariana Islands
France
Indonesia
Dominican Republic
Equatorial Guinea
Palau
Germany
Iran
El Salvador
Eritrea
Papua New Guinea
Gibraltar
Iraq
Greenland
Eswatini
Pitcairn Islands
Greece
Israel
Grenada
Ethiopia
Samoa
Guernsey
Japan
Guadeloupe
Gabon
Solomon Islands
Hungary
Jordan
Guatemala
Ghana
Timor-Leste
Iceland
Kazakhstan
Haiti
Guinea
Tokelau
Ireland
Kuwait
Honduras
Guinea-Bissau
Tonga
Isle of Man
Kyrgyzstan
Jamaica
Kenya
Tuvalu
Italy
Laos
Martinique
Lesotho
United States Minor Outlying Islands
Jersey
Lebanon
Mexico
Liberia
Vanuatu
Latvia
Macau
Montserrat
Libya
Wallis and Futuna
Liechtenstein
Malaysia
Nicaragua
Madagascar
Lithuania
Maldives
Panama
Malawi
Luxembourg
Mongolia
Puerto Rico
Mali
Malta
Myanmar (Burma)
Saint Kitts and Nevis
Mauritania
Moldova
Nepal
Saint Lucia
Mauritius
Monaco
North Korea
Saint Pierre and Miquelon
Mayotte
Montenegro
Oman
Saint Vincent and the Grenadines
Morocco
Netherlands
Pakistan
Saint-Barthélemy
Mozambique
North Macedonia
Palestine
Sint Maarten
Namibia
Norway
Philippines
The Bahamas
Niger
Poland
Qatar
Trinidad and Tobago
Nigeria
Portugal
Saudi Arabia
Turks and Caicos Islands
Republic of the Congo
Romania
Singapore
U.S. Virgin Islands
Reunion
Russia
South Korea
United States
Rwanda
San Marino
Sri Lanka
Saint Helena
Serbia
Syria
São Tomé and Príncipe
Slovakia
Taiwan
Senegal
Slovenia
Tajikistan
Seychelles
Spain
Thailand
Sierra Leone
Svalbard and Jan Mayen
Türkiye
Somalia
Sweden
Turkmenistan
South Africa
Switzerland
United Arab Emirates
South Sudan
Ukraine
Uzbekistan
Sudan
United Kingdom
Vietnam
Tanzania
Vatican City
Yemen
The Gambia
Togo
Tunisia
Uganda
Western Sahara
Zambia
Zimbabwe