Publish your products
RTL 120 Built-in local unit with 0...10V and relay outputs (Multizone System)

RTL 120 Built-in local unit with 0...10V and relay outputs (Multizone System)

RTL 120 is the unit (SLAVE) of the Multizone System for the control of heating and other functions in a single zone. 

  • Housed in a standard built-in 503 enclosure  (it is compatible with the switchboards and plates commonly on sale).
  • Receives power from an auxiliary power supply
  • Controls the local thermal units by means of:
    • On-Off zone valve with 230 V~ actuator and modulation unit with 0...10 Volt – input
    • On-Off zone valve with 24 V~ (or other voltages) actuator, and modulation unit with 0...10 Volt – input
    • Zone valve with 24 V~ (or other voltages) thermal actuator, and modulation unit with 0...10 Volt – input
    • Fixed or variable speed zone circulation pump
    • Zone burner or small boiler with 0...10 Volt – input in POWER or TEMPERATURE
    • On-Off valve and fan-coil ventilator switch with 0...10 Volt – input
    • Any other device that can be controlled via a three-point relay and with 0...10 Volt input –
  • Room sensor (internal or external)
  • Complete configuration of the limits and mode of use permitted to user
  • Three On-Off inputs to be programmed as required
  • Large display with simplified readout 
  • Three operational push-button switches with “intuitive” use 
  • Ability to work even in case of breakdown of the communication with the central unit
  • Customisable unit name 
Specification
    • Power supply: 13 V –
    • Maximum consumption: 30 milliWatt
    • Voltage-free output contacts:
      • maximum switched voltage 250 V ~
      • maximum switched current 5 (1) A
    • Protection: IP40
    • Ambient temperature:
      • operating 0 … 45°C
      • storage – 25 … + 60°C
    • Ambient humidity class: F DIN 40040
    • Internal or remote room sensor
      • Measurement range: 0 … + 50 °C
      • Sensor error: +/– 0.3 °C
    • 1 Relay for selection heating/conditioning 
    • 1 0...10 Volt output
      • Maxiumum input load: 1mA 
      • Min. and Max. limits can be set on the Master unit
    • 3 Programmable auxiliary inputs, with the following acquisition time:
      • Switch minimum: 300 msec
      • Button minimum: 150 msec.
    • Programs Heating/Condit. for individual zones
      • 24hour programs: 1 … 7
        • 24hour times: 6
      • Weekly programs: 0 …7
      • Programs with limited time (P. LIMIT): 1
        • Maximum time limited to 7 days & 23 hours
      • Annual programs: 1...5
    • All the alarm functions are available in order to have instantaneous control of the zone situation
    • Management by Master Via P-Loc Bus
Technical specification
  • Unique ref.costergroup-rtl120
  • Product familyMULTIZONE SYSTEM
  • Product groupHEATING
  • TypeObject (single object)
  • Date of publishing2020-03-11
  • Edition number1
  • Height (mm)50
  • Width (mm)92
  • Depth (mm)39.5
Related
  • Material mainABS
  • Material secondaryNylon
  • Designed inItaly
  • Manufactured inItaly
Classification
  • BIMobject CategoryHVAC - Control Panels

Region availability

Europe
Åland Islands
Albania
Andorra
Austria
Belarus
Belgium
Bosnia and Herzegovina
Bulgaria
Croatia
Cyprus
Czech Republic
Denmark
Estonia
Faroe Islands
Finland
France
Germany
Gibraltar
Greece
Guernsey
Hungary
Iceland
Ireland
Isle of Man
Italy
Jersey
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Moldova
Monaco
Montenegro
Netherlands
North Macedonia
Norway
Poland
Portugal
Romania
Russia
San Marino
Serbia
Slovakia
Slovenia
Spain
Svalbard and Jan Mayen
Sweden
Switzerland
Ukraine
United Kingdom
Vatican City