Publish your products
Fire rated uninsulated access door for walls only
Cendrex

Fire rated uninsulated access door for walls only

Provide reliable fire protection to your access with the PFN Fire-Rated Uninsulated Access Door with Exposed Flange from Cendrex. Designed with a self-latching tool-key operated slam latch and ring operated slam latch, this door helps limit the spread of fire without additional thermal insulation. Suitable for fire-rated walls, it features a 16 gauge cold rolled steel construction and a continuous piano hinge to ensure safety and durability in different commercial and industrial settings.

Contractors, architects, engineers, and industry professionals choose our PFN model for its reliable fire-rated features and durability.

Perfect for emergency corridors in public buildings and storage areas in warehouses, this access door limits the spread of fire without the need for additional thermal insulation.

Key Features

  • Inside Panel Release: All doors over 12" X 12 inches are equipped with an inside panel release for added convenience and accessibility.
  • Uninsulated: Fired-rated uninsulated access door that can be used on fire-rated walls.
  • Limit Fire Spread: Designed to limit the spread of fire.

Technical Details

  • Installation: Suitable for installation on walls only.
  • Material: Constructed from 16 gauge cold rolled steel.
  • Locking Mechanism: Features a self-latching tool-key operated slam latch and ring operated slam latch, both included.
  • Hinge: Equipped with a continuous piano hinge. Hinge location: Hinges must be located on the second dimension (height).
  • Flange: Designed with an 1" exposed flange.
  • Frame: 2½ " in depth, made of cold rolled steel.
  • Rough opening: Door sizes + ¼ " or + 6mm.
  • Inside panel release: Mechanisms to allow panels to open from inside, standard on all doors over 12" X 12 inches.
  • Finish: High quality white powder coat primer.
  • Packaging: Individually wrapped, 1 door per box.

Fire rated access doors, for vertical use, are subject to the following:

  • Certification: UL 10B (2009), NFPA 252 (2012), CAN/ULC S104 (R1985), CAN/ULC S104 (2010).
  • Rating achieved: 1-½ hours, neutral/negative pressure.
  • Maximum size: 36" x 36" (914 mm x 914 mm), maximum area of 1296 in², tolerance on height and width limitation is more or less 3" (76mm) as long as the area does not exceed 1296 in².
  • Temperature rise: No rating achieved.

All the dimensions and options that you want in 5 days! Choose from over 100 access panel designs and 30 add-on options for personalized solutions, all delivered within the shortest lead time in the industry.

Ready to elevate your projects with our PFN Fire-Rated Uninsulated Access Door with Exposed Flange? Download our catalogue now to explore our full range of products and discover the perfect solution for your next project.

Cendrex, a leader in the manufacturing of custom and odd-sized doors since 1985, is committed to providing high-quality rated and non-rated access panels with the industry's shortest lead time. Our commitment to excellence and customization makes us the go to choose for professionals seeking reliable and elegant solutions.



CENDREX

1-800-479-1489

info@cendrex.com

cendrex.com

Specification
    • Material

      16 gauge cold rolled steel

    • Hinge

      Continuous piano hinge. Hinge location: Hinges must be located on the second dimension (height).

    • Locking mechanism

      Self-latching tool-key operated slam latch and ring operated slam latch, both included.

    • Flange

      1" exposed flange

    • Frame

      2½ " in depth, made of cold rolled steel

    • Rough opening

      Door sizes + ¼" or + 6mm

    • Inside panel release

      Mechanisms to allow panels to open from inside, standard on all doors over 12" X 12 inches.

    • Finish

      High quality white powder coat primer.

    • Packaging

      Individually wrapped, 1 door per box.

    • Fire rated access doors, for vertical use, are subject to the following:
      • Vertical wall assemblies

        Fire rated access doors, for vertical use, are subject to the following:

      • Certification

        UL 10B (2009), NFPA 252 (2012), CAN/ULC S104 (R1985), CAN/ULC S104 (2010).

      • Rating Achieved

        1-½ hours, neutral/negative pressure

      • Maximum size

        36" x 36" (914 mm x 914 mm), maximum area of 1296 in², tolerance on height and width limitation is more or less 3" (76mm) as long as the area does not exceed 1296 in².

      • Temperature rise

        No rating achieved

Technical specification
  • Unique ref.cendrex-pfn
  • Product familyAccess Doors
  • Product groupFire Rated
  • TypeObject (single object)
  • Date of publishing2013-12-09
  • Edition number1
Related
  • Designed inCanada
  • Manufactured inCanada
Classification
  • BIMobject CategoryConstruction - Access doors & panels
  • Uniclass 2015 CodeTE_10_40_10
  • Uniclass 2015 DescriptionAccess doors and traps
  • CSI MasterFormat 2014 Code08 31 00
  • CSI MasterFormat 2014 TitleAccess Doors and Panels
  • OmniClass Number23-17 11 27
  • OmniClass TitleAccess Doors

Region availability

North America
Canada
United States