SW100/125; EI30; Austria; Shaft wall, single metal stud frame, double-layer cladding
SW100/125; EI30; Austria; Shaft wall, single metal stud frame, double-layer cladding

    SW100/125; EI30; Austria; Shaft wall, single metal stud frame, double-layer cladding

    B+M partition wall, lining and shaft wall systems are unique in regards to flexibility of usable system components. IntraProfil® metal studs and channels are the core elements of every B+M system construction. Additionally required system components of all within the "B+M Markensiegel" mentioned brands may be used and combined accordingly to B+M installation guidelines and testings.
    Specification
    • 125 mm shaft wall on a single IntraProfil ® CW100 steel structure with 2 layers of 12.5 mm fire- rated gypsum plasterboard GKF(DF)/GKFI(DFH2) on one side.

    Technical specification
    • Unique ref.BM_SW-100-125_EI30_metal_double-layer-cladding-A
    • Product familyAT_Wall Partition
    • Product groupshaft wall, 1 stud, 2 layers, fire resistance
    • TypeObject (single object)
    • Date of publishing2022-03-24
    • Edition number1
    • Height (mm)4500
    • Depth (mm)125
    Related
    • Material mainGypsum
    • Material secondarySteel
    • Designed inAustria
    • Manufactured inAustria
    Classification
    • BIMobject CategoryWalls - Internal Walls
    • IFC classificationWall
    • UNSPSC nameGypsum board
    • UNSPSC code30161509
    • Uniclass 2015 CodeEF_25_10
    • Uniclass 2015 DescriptionWalls
    • CSI MasterFormat 2014 Code09 21 16.23
    • CSI MasterFormat 2014 TitleGypsum Board Shaft Wall Assemblies
    • OmniClass Number23-15 11 11 11
    • OmniClass TitleGypsum Board Fixed Partitions
    • CSI UniFormat II CodeC1010
    • CSI UniFormat II TitlePartitions

    Region availability

    Europe
    Austria