Publish your products
PIANO-SYSTEM ND+I Rectangular Cowl

PIANO-SYSTEM ND+I Rectangular Cowl

Piano System Cowl ND+I -Primarily designed for building roofs to protect various types of
installations: ventilation, air conditioning, plumbing, electrical from
atmospheric conditions. They come in both "without" and "with" pre-made
technical openings, rectangular and/or circular, in any quantity, which
can be used for the installation of roof intakes and outlets, sanitary
outlets, or electrical cable conduits in buildings, including
residential, collective housing, and public utility buildings. They can
also be used in warehouses, industrial buildings, and utility buildings.

The Piano System Cowl ND+I with a rectangular cross-section consists
of a insulinoterapia straight duct bent at a 90-degree angle and a cover
with a shield. The inner duct shell and the outer duct shell are
connected by welding at the point of contact. The duct and cover are
made of galvanized steel sheet DX51D with a zinc coating Z275 according
to the PN-EN 10346:2015 standard. Between them, there is polyurethane
foam (PUR) insulation with a thickness of 25 ÷ 100 mm. The dimensions of
the outer duct shell depend on the thickness of the applied foam
insulation layer. The minimum thickness of the inner and outer duct
shell sheet metal is 0.5 mm.
Connections (collar frames) used in the inner duct shell and the outer
duct shell are made of P-20 or P-30 profiles and N-20 or N-30 corners,
made of galvanized steel sheet DX51D+Z275 according to the PN-EN
10346:2015 standard.

Dimensions (duct side): 100-4000 mm

Specification

  • Depending on the type of installation that Piano System Cowl ND+I are intended to protect, they come in several variants that can be freely combined or modified as needed:VARIANT I - SCREW-ON CAP for ducts with screws and self-locking nutsVARIANT II - HINGED CAP - Hinged flapOption 1 - CAP WITHOUT OPENINGSOption 2 - CAP WITH OPENINGS - quantity, shape, and dimensions of openings according to the Customer's specificationSide A - SIDES WITHOUT OPENINGSPiano System Cowl ND+I without technical openingsSide B - SIDES WITH OPENINGSPiano System Cowl ND+I with a rectangular or circular technical opening, ready for installation, e.g., wall intakes/outletsThe number of openings is arbitrary on each side of the cap.

    Types:

    1. [I-1-A] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 1 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    2. [I-1-B] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 1 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)
    3. [I-2-A] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 2 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    4. [I-2-B] Piano System Cowl ND+I; VARIANT I (SCREW-ON CAP); Option 2 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)
    5. [II-1-A] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 1 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    6. [II-1-B] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 1 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)
    7. [II-2-A] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 2 (CAP WITHOUT OPENINGS); Side A (SIDES WITHOUT OPENINGS)
    8. [II-2-B] Piano System Cowl ND+I; VARIANT II (HINGED CAP); Option 2 (CAP WITHOUT OPENINGS); Side B (SIDES WITHOUT OPENINGS)

    Variants: SCREW-ON CAP HINGED CAPSCREW-ON CAP Variant I XHINGED CAP X Variant IICAP WITHOUT OPENINGS SIDES WITHOUT OPENINGS Variant I Option 1 Side A Variant II Option 1 Side ACAP WITHOUT OPENINGS SIDES WITH OPENINGS Variant I Option 1 Side B Variant II Option 1 Side BCAP WITH OPENINGS SIDES WITHOUT OPENINGS Variant I Option 2 Side A Variant II Option 2 Side ACAP WITH OPENINGS SIDES WITH OPENINGS Variant I Option 2 Side B Variant II Option 2 Side B

    CONSTRUCTION

    1. Inner shell
    2. Outer shell
    3. Polyurethane foam insulation layer
    4. Collar/angle bracket adjacent to the ceiling
    5. Roofing membrane - roof insulation layer
    6. Ceiling
    7. Inner duct connection frame
    8. Outer duct connection frame
    9. Expansion plug
    10. Rivet
    11. Ceiling insulation layer
    12. Seal
    13. Technical opening


    The inner duct shell and the outer duct shell of the straight duct are joined longitudinally using sheet metal locks (Pittsburgh type lock) or welded. The corners of the collar frames are sealed with silicone sealant.

    Assembly variants of the Piano System Cowl ND+I cover:

    1. Cover connected on one side with steel hinges, mounted using rivets, creating a hinged flap, which can additionally be secured with M8 screws (for N+P20 collar) or M10 screws (for N+P30 collar) and self-locking nuts.
    2. Assembly of the cover using collar connections, fastened with M8 screws (for N+P20 collar) or M10 screws (for N+P30 collar) according to DIN 933 or PN-EN ISO 4017:2014 and self-locking nuts. The Nasada ND+I is installed on the ceiling using expansion plugs, one in each corner and on the sides at a distance of every 0.5 m.Collar connection frames of the cover with the duct of the Piano System Cowl ND+I (for the outer duct shell) elements with a side length greater than 500 mm can (but do not have to) be additionally reinforced with sheet metal clamps. The maximum distance between the clamps at the corner collar connection and relative to each other should be 500 mm.
Technical specification
  • Unique ref.piano-system-ndi-rectangular-cowl
  • Product familyVentilation ducts
  • Product groupPre-insulated ventilation ducts
  • TypeBuilding Material
  • Date of publishing2023-09-25
  • Edition number1
Related
  • Material mainGalvanized steel
  • Material secondaryPolyurethane
  • Designed inPoland
  • Manufactured inPoland
Classification
  • BIMobject CategoryHVAC - Ductwork
  • IFC classificationDuct Segmnt
  • ETIM CodeEC000059
  • ETIM NameInstallation duct
  • Uniclass 2015 CodePr_20_85_12
  • Uniclass 2015 DescriptionBunds and ducts
  • CSI MasterFormat 2014 Code23 31 00
  • CSI MasterFormat 2014 TitleHVAC Ducts and Casings
  • OmniClass Number23-33 49 00
  • OmniClass TitleHVAC Ductwork

Region availability

Europe
Åland Islands
Albania
Andorra
Austria
Belarus
Belgium
Bosnia and Herzegovina
Bulgaria
Croatia
Cyprus
Czech Republic
Denmark
Estonia
Faroe Islands
Finland
France
Germany
Gibraltar
Greece
Guernsey
Hungary
Iceland
Ireland
Isle of Man
Italy
Jersey
Latvia
Liechtenstein
Lithuania
Luxembourg
Malta
Moldova
Monaco
Montenegro
Netherlands
North Macedonia
Norway
Poland
Portugal
Romania
Russia
San Marino
Serbia
Slovakia
Slovenia
Spain
Svalbard and Jan Mayen
Sweden
Switzerland
Ukraine
United Kingdom
Vatican City