Publish your products
Equipment Enclosure Acoustics
Equipment Enclosure Acoustics
Equipment Enclosure Acoustics

    Equipment Enclosure Acoustics

    The Troy “Isolate” System for equipment enclosures consists of designs featuring Portland cement/ wood fiber boards and organic mineral wool that combined provides superior performance in loud noise situations. The Troy system can be shipped anywhere in the world and installed by local labor according to Troy designs. Troy's expertise has been servicing the equipment enclosure industry since 2005.

    .

    key words: HVAC, fan, mitigate, loud machines, decibels, electrical, exterior, outside, cabinet, STC, NRC, equipment, enclosures

    Specification
    • Wood Fiber and Portland Cement Boards

      Troy Boards (TB) are produced from Portland Cement and wood fibers resulting as the superior acoustical performance material for loud noise environments. Troy Boards are low VOC and are sourced from sustainably managed forest. Troy Wool (TW) is a 2.5 lbs. density mineral wool, produced from Basalt rocks. The Troy System materials TB and TW are natural and organic in composition.

      Physical Properties

      ¨ Zero (0) Flame Spread as per UL

      ¨ Zero (0) Smoke Developed as per UL

      ¨ NRC of .85 for Baffles/Safety Ceiling

      ¨ NRC of .89 for Range Walls

      ¨ Acoustical tests per Riverbank Laboratory

      ¨ NRC 1.0 for absorption ceiling

      ¨ Waterproof, can be used outdoors

      ¨ Does not support Fungi Growth

      ¨ Does not support Microbial growth

      Applicable Standards

      ¨ Acoustical per Riverbank Laboratory

      ASTM C423-09a, ASTM E795-05

      ¨ CAC per USG Testing

      ASTM E1414-16

      ¨ Microbiological Testing per Accugen Labs

      ASTM G21, ASTM E 2180

      ¨ Splatter & Ricochet Protection testing by USAF

      ¨ Fire Rating per Underwriters Laboratory ASTM E84 as per UL 723


      Load Weights

      ¨ 1” TB and 2” TW for Direct attach to Ceiling Decks is 3.5 lbs./sq. ft.

      ¨ 2” TB and 2” TW for Direct Attach to Walls is 5 lbs./sq. ft.

      ¨ 1” TB and 6” TW for Suspended Absorption Ceilings is 3.5 lbs./sq. ft.

      OTHER

      ¨ Fire Rating per Underwriters Laboratory

      Report # R27255-20120503

      ¨ Acoustical Performance per Riverbank Laboratory

      Report # RAL– A11-205, A11-206

      ¨ Anti-Fungal and Anti-Microbial tests per

      Accugen Laboratory Report # 175034, # 175035

    Technical specification
    • Unique ref.equipment-enclosure-acoustics
    • Product familyAcoustics
    • Product groupEquipment Enclosures
    • TypeObject (single object)
    • Date of publishing2022-09-07
    • Edition number1
    Related
    • Material mainCementitious
    • Material secondaryWood
    • Designed inUnited States
    • Manufactured inUnited States
    Classification
    • BIMobject CategoryConstruction Materials - Acoustic Panels & Accessories
    • IFC classificationBuilding Element
    • Uniclass 2015 CodeSs_25_25_05
    • Uniclass 2015 DescriptionAcoustic panel systems
    • CSI UniFormat II CodeF1030
    • CSI UniFormat II TitleSpecial Construction Systems

    Region availability

    North America
    Anguilla
    Antigua and Barbuda
    Aruba
    Barbados
    Belize
    Bermuda
    British Virgin Islands
    Canada
    Caribbean Netherlands
    Cayman Islands
    Collectivity of Saint Martin
    Costa Rica
    Cuba
    Curaçao
    Dominica
    Dominican Republic
    El Salvador
    Greenland
    Grenada
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Martinique
    Mexico
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Kitts and Nevis
    Saint Lucia
    Saint Pierre and Miquelon
    Saint Vincent and the Grenadines
    Saint-Barthélemy
    Sint Maarten
    The Bahamas
    Trinidad and Tobago
    Turks and Caicos Islands
    U.S. Virgin Islands
    United States