Publish your products
Area of Rescue 8-Station Analog Command Unit

Area of Rescue 8-Station Analog Command Unit

Area of Refuge/Rescue (AOR) Command Unit (model AOR-8) is part of Talkaphone’s total AOR solution that accommodates up to 8 ADA-compliant Area of Refuge/Rescue stations.

  • Accommodates up to 8 Area of Rescue stations
  • AOR stations are powered by the command unit
  • Command unit can route an emergency phone call to a 911 center or other designated location

It consists of a command unit, a selected number of AOR stations (flush or surface mounted), and AOR signage to accommodate the selected number of AOR stations. The ADA-compliant AOR stations are powered by the command unit using one twisted-shielded pair cable from each AOR station to the command unit.

When the user initiates an emergency call from an AOR station, a tone is heard to confirm the call has been placed and an LED light indicates the call has been received. At the same time, the command unit’s strobe starts flashing and the siren is initiated. If there are other callers on the line, the command unit receives and queues the call. Each queued emergency call is displayed as a flashing red light on the command unit, which can be labeled for easy location identification. AOR stations can also be programmed to play a location identifier message when a call is answered. An active call is displayed as solid red. The command unit’s siren deactivates when the call is answered by local fire personnel. The strobe will deactivate only when all emergency lines have been cleared. Includes hardware to detect short/open conditions on cabling for each area of rescue station. With this update, the system will also recognize a general ground fault condition. Such trouble conditions will be annunciated and visually indicated at the AOR Series Command Unit.

The command unit can route an emergency phone call to a 911 center or other designated location via a TELCO line if no one is available to answer the call after an installer programmed amount of time. An uninterruptible power supply (UPS) is included to provide more than 4 hours of backup of the complete communications system.

Specification
  • Features and Benefits

    • On-site calling requires no outside phone lines
    • Off-site calling requires only one phone line for up to 8 Stations: line seizure eliminates need for dedicated phone line
    • Blinking LEDs indicate Stations that are waiting to be answered. When first call is completed, 2nd call is automatically placed, phone rings and strobe/siren is activated
    • Includes hardware to detect short/open conditions on cabling for each area of rescue station. With this update, the system will also recognize a general ground fault condition. Such trouble conditions will be annunciated and visually indicated at the AOR Series Command Unit.
    • Siren is activated when Emergency call is first detected, shuts off when call has been answered
    • Strobe is activated when Emergency call is first detected and remains active for duration of call
    • Built-in UPS provides 4-hour power back up in case of power failure
    • Includes built-in phone

    Approvals: Power Supply Approvals: EMI conducted and radiated EN61204-3 Class A, Safety EN60950, UL294 Access Control, UL 603 Burglar Systems, UL 1076 Proprietary Burglar, UL 1481 Fire Alarm Systems
    Call Station Options: Indoor Flush Mount Model: AOR-CSE-FM, Indoor Surface Mount Model: AOR-CSE-SM
    Communication: Lighted phone with 12-button keypad receives and selectively originates calls
    Connectivity: Supports one (1) analog phone line (PSTN line) for off-site dialing
    Environment: For indoor use
    Fault Monitoring: Activation of any AOR Station, opens/shorts on AOR Station cabling, 110VAC input power failure (primary power loss), low battery backup (low voltage detected), and system ground fault
    Mounting: Surface mount or recess mount with optional trim ring (Model AOR-TR16). Strobe/sounder mounts to standard 4-inch square box.
    Power: 120VAC, 0.5 A (max)
    Supervision Relay: Activation of Any AOR Station: Contact closure (relay) output; Open/Short Fault on AOR Stations: Contact closure (relay) output; AC Input Power Failure: 24VDC output; Low Battery (Low Voltage Detected): Low/short output; and System Ground Fault: Contact closure (relay) output.
    Wiring: One (1) twisted, shielded pair per station not to exceed 25 ohms resistance

    Keywords: two way emergency communication, emergency panel, emergency response panel, emergency panel alarm, emergency communication system

Technical specification
  • Unique ref.aor-8_area-of-rescue-8-station-command-unit
  • Product familyArea of Rescue
  • Product groupAOR Analog Series
  • TypeObject (single object)
  • Date of publishing2022-12-05
  • Edition number1
Related
  • Material mainSteel
  • Designed inUnited States
  • Manufactured inUnited States
Classification
  • BIMobject CategoryElectronics - Communication
  • UNSPSC nameTelecommunications remote access unit
  • UNSPSC code43221521
  • Uniclass 2015 CodePr_70_75_88
  • Uniclass 2015 DescriptionTelecoms equipment
  • CSI MasterFormat 2014 Code27 32 26
  • CSI MasterFormat 2014 TitleRing-Down Emergency Telephones
  • OmniClass Number23-37 27 17
  • OmniClass TitleEmergency Call Equipment

Region availability

North America
Anguilla
Antigua and Barbuda
Aruba
Barbados
Belize
Bermuda
British Virgin Islands
Canada
Caribbean Netherlands
Cayman Islands
Collectivity of Saint Martin
Costa Rica
Cuba
Curaçao
Dominica
Dominican Republic
El Salvador
Greenland
Grenada
Guadeloupe
Guatemala
Haiti
Honduras
Jamaica
Martinique
Mexico
Montserrat
Nicaragua
Panama
Puerto Rico
Saint Kitts and Nevis
Saint Lucia
Saint Pierre and Miquelon
Saint Vincent and the Grenadines
Saint-Barthélemy
Sint Maarten
The Bahamas
Trinidad and Tobago
Turks and Caicos Islands
U.S. Virgin Islands
United States