Product Reference
Rada V12 Concealed Thermostatic Shower Valve (1.1651.002)
Standard product features
Connections:
• Inlets: 15 mm compression.
• Outlet: ½” BSP Flat Face/ 15 mm compression.
• Standard connections are: hot- left, cold- right, outlet- bottom or top.
Operation:
The Rada V12 is operated via a single sequential control which when rotated initially opens the valve, then increases temperature from cold to a pre-set maximum.
Temperature Range:
• Temperature range from cold to preset maximum.
• The maximum temperature that can be selected is factory set at approximately 43°C, but this can be reset on site if required (by an authorised person).
• Thermostatic control ± 1°C within the range 35–45°C (assuming supplies of 15–65°C hot at nominally equal pressures).
Note: In the event of loss of either supply, the valve will automatically shut off. Minimum temperature differential of blend to either supply 10°C. For reasons of general safety, hot water storage temperatures should be maintained at between 60–65°C where serving ablutionary applications. The mixing valve can accept temporary excursions above 85°C without damage, however operation at such elevated temperatures is not recommended.
Supply:
• Cold water temperature range 5–25°C.
• Hot water temperature range (recommended) 60–65°C.
• Maximum hot water temperature 85°C.
Pressure/ Flow rates:
Dynamic supply pressure (Running):
• Minimum: 0.1 Bar.
• Maximum: 5 Bar.
• Maximum Static: 10 Bar.
• Minimum flow rate: 3 L/min.
• Maximum flow rate: 40 L/min.
Materials:
• Body and Elbows: Chrome plated DZR brass.
• Lever: Chrome plated zinc die cast with ABS trim.