Product Reference
Rada LR head (2.1640.001)
Rada LR operating system (1.1640.002)
Infra-red sensor and 1/2" solenoid valve.
Rada LR sensor (1.1640.003)
Standard product features
Head size (w x h x d):
75 x 75 x 71.4 mm.
Materials:
• Sensor: Brass, chrome finish.
• Showerhead: Brass, polished chrome finish.
• Spray cartridge: Engineering plastic.
Temperature range:
Designed to accept water supplied between 5–90°C.
Pressure range:
• Recommended minimum maintained pressure at the inlet: 0.5 bar.
• Maximum maintained pressure at the inlet of the fitting: 5.0 bar.
Spray performance:
Minimum flow rate required: 6 litres/ minute.
Electrical input:
• Protection class sensor: IP65.
• Supply voltage: 12V AC + 10% 50/60Hz, via Rada pulse control box.