Product Reference
Rada Mono Control MC122 Operating System (1.1495.010)
Accessories
Rada Universal 12V AC Transformer
Standard product features
Operation:
• When the sensor is activated, if the pre-flush option has been selected, there will be an approximate 2 second delay and 2 second pre-flush.
• When there has been 5 seconds of inactivity the flush is activated for the duration selected (3 - 10 seconds in 1 second intervals).
• The solenoid valve is supplied complete with an integral isolator and filter.
Flush timing:
• The system provides an optional pre-flush of 2 seconds if a human body is detected, and then initiates a flush cycle after use.
• Flush duration can be pre-set between 3 and 10 seconds in increments of 1 second, by the adjustment of the integral timing dial.
• A duty flush is incorporated, every 24 hours after use.
Materials:
• Sensor: Chrome plated durable engineering plastic with shatterproof plastic sensing window.
• Solenoid valve: Fibreglass polyamide body.
Pressure:
• Solenoid valve: 0.20 - 10 bar.
Electrical:
• Sensor protection class: Electronic module IP65.
• Supply voltage: 12V AC + 10% 50/60Hz, via Rada Universal 12V AC transformer (not included).
• Power consumption: 6 VA.
Operating temperatures:
• Ambient temperature range: 5–40°C.
• Maximum humidity: 80%.
Accessories:
• Rada Universal 12V AC Transformer.