Publish your products
Protan Extensive Green roof system on steel substrate
Protan Extensive Green roof system on steel substrate
Protan Extensive Green roof system on steel substrate
    PROTAN

    Protan Extensive Green roof system on steel substrate

    PROTAN EXTENSIVE GREEN ROOF SYSTEM ON STEEL SUBSTRATE

    Extensive green roofs are characterised by the roof being covered with a thin layer of soil or growing medium mats, typically planted with succulent and moss species.

    Extensive green roofs generally require little maintenance and offer great potential in terms of applications. They are light weight and do not require a heavy-duty load-bearing structure which is required by intensive green roofs

    The wind forces on the roof have to be taken into account on all roof structures. The sedum mats can only be laid in the warm season. Due to the low weight of the green roof layers, the membrane has to be calculated to withstand wind loads and may have to be fastened mechanically.

    The membrane has to satisfy fire safety requirements without cover until the sedum mats are installed or in the event that the sedum mats are not fire rated. Our membrane is self-extinguishing and is classified according to EN 13501-5. Larger roofs require fire barriers. At upstands and penetrations the growing medium has to be separated by barriers in the form of concrete blocks, pebbles, etc., to prevent fire from spreading.

    Protan SE Titanium + membrane has been certified root resistant in accordance with the FLL test (Forschungsgesellschaft Landschaftsentwicklung Landschaftsbau) and does not require extra protection such as root barriers.

    CONSTRUCTION STRUCTURE:

    • EXTENSIVE GREEN ROOF LAYERS - SEDUM / DRAINAGE & RESERVOIR LAYER
    • PROTAN SE TITANIUM + MEMBRANE
    • PROTAN APPROVED FASTENERS
    • INSULATION
    • VAPOUR CONTROL LAYER
    • STEEL SUBSTRATE

    PROTAN SE TITANIUM+ MEMBRANE

    • Protan SE Titanium + membrane is a root-resistant PVC membrane with a polyester reinforcement that is designed for extensive sedum roofs. The polyester reinforcement makes it optimal for mechanical fastening when necessary. The product is well suited with regards to protection against UV rays, variations in temperature and micro-organisms.
    • Because the sedum plants can only be installed during the summer, it is important to use a membrane that can be both mechanically fastened and fire classified. Protan SE Titanium+ membrane is Broof (t1) and Broof (t2) fire classified.

     SYSTEM INSTALLATION METHOD:

    • Protan Standard Overlap System - The membrane is fastened to the substrate along the longitudinal sheet edges and overlapped by the adjoining roll. The two rolls are welded together using hot air.
    • Protan Prefabricated Sheets system is the best and fastest solution in wind-exposed areas, so it is ideal when the roof has to be covered quickly. The membrane is provided in 2 or 4 metre widths with high strength strips welded longitudinally on the underside for mechanical fastening.
    • The Protan Secret Fix System uses a membrane in 2-metre widths with extra strong strips welded transversely to the underside for mechanical fastening.

    Please contact Protan for further advice.

    FASTENERS:

    • Protan approved - must be calculated according to EN 1991-1-4 alongside national annexes and local regulations.

    INSULATION:

    Various types of insulation can be used in combination with Protan membranes and can be flat insulation or sloped insulation. The material type and design will depend on the building design, fire classification and local regulation requirements.

    • Mineral wool (MW) – can be glass or stone type
    • Polyisocyanurate (PIR) - foil faced
    • Combination EPS-MW

    VAPOUR CONTROL LAYER:

    • Polyethylene
    • Bitumen

    STEEL SUBSTRATE:

    • Profiled metal decking consists of galvanised steel. Minimum recommended thickness 0.7mm to EN 10346 Fe E280G Z275 or local regulations.
    Specification
    • TECHNICAL SPECIFICATION

      Protan SE Titanium + specifications are subject to availability and may not be available or approved in all countries/regions.

      Membrane thickness:

      • 1.6 mm 

      Membrane standard widths: 

      • 1.0 m 
      • 2.0 m
      • 3,96 m (prefabricated)

      Membrane standard roll lengths: 

      • 20 m 

      Membrane colours (nearest RAL code):

      • Light grey F91- RAL 7040

       FIRE CLASSIFICATION

      Protan SE Titanium + exposed roof systems are classified according to EN 13501-5. Fire classifications are available on a variety of constructions and insulation types. Please contact Protan for further information or refer to the relevant technical approvals.

    Technical specification
    • Unique ref.extensive_green_steel_eu
    • Product familyRoofing
    • Product groupSingle Ply Membrane
    • TypeObject (single object)
    • Date of publishing2019-02-19
    • Edition number1
    Related
    • Material mainPVC
    • Material secondaryInsulation
    • Designed inNorway
    • Manufactured inNorway
    Classification
    • BIMobject CategoryConstruction Materials - Waterproofing & Membranes
    • IFC classificationRoof
    • UNSPSC nameRoofing membranes
    • UNSPSC code30151505
    • Uniclass 2015 CodeSs_30_40_30_80
    • Uniclass 2015 DescriptionSingle layer sheet warm roof covering systems
    • CSI MasterFormat 2014 Code07 50 00
    • CSI MasterFormat 2014 TitleMembrane Roofing
    • OmniClass Number23-13 39 31 11 27
    • OmniClass TitlePolyvinyl chloride (PVC) Single Layer Roof Membranes
    • CSI UniFormat II CodeB3010
    • CSI UniFormat II TitleRoof Coverings

    Region availability

    Europe Asia
    Åland Islands
    Türkiye
    Albania
    Andorra
    Austria
    Belarus
    Belgium
    Bosnia and Herzegovina
    Bulgaria
    Croatia
    Cyprus
    Czech Republic
    Denmark
    Estonia
    Faroe Islands
    Finland
    France
    Germany
    Gibraltar
    Greece
    Guernsey
    Hungary
    Iceland
    Ireland
    Isle of Man
    Italy
    Jersey
    Latvia
    Liechtenstein
    Lithuania
    Luxembourg
    Malta
    Moldova
    Monaco
    Montenegro
    Netherlands
    North Macedonia
    Norway
    Poland
    Portugal
    Romania
    Russia
    San Marino
    Serbia
    Slovakia
    Slovenia
    Spain
    Svalbard and Jan Mayen
    Sweden
    Switzerland
    Ukraine
    United Kingdom
    Vatican City