    The Protan Adhered System can be used on both warm and cold roof structures, new build and renovation projects. In some countries adhesion is a common roofing method, but this solution cannot be installed during cold or wet weather.

    This type of solution can be appropriate on buildings with high humidity, such as swimming pools, and on roofs with, for example, a wood wool deck, where mechanical fastening is difficult.

    For fully adhered roofing systems, Protan has developed the Protan EX-A membrane with polyester fleece on the reverse.

    CONSTRUCTION STRUCTURE:

    • PROTAN EX-A MEMBRANE
    • MEMBRANE ADHESIVE
    • INSULATION
    • INSULATION ADHESIVE OR INSULATION FASTENERS
    • VAPOUR CONTROL LAYER
    • CONCRETE SUBSTRATE

    PROTAN EX-A MEMBRANE:

    Protan EX-A membrane is a polyester reinforced PVC membrane which has a polyester fleece laminated on the reverse side. The membrane is to be installed in an exposed adhered roof system in which it is bonded to polyisocyanurate (PIR) or suitable mineral wool insulation, please contact Protan for approved insulation types.

    MEMBRANE ADHESIVE:

    • Protan ProBond moisture curing PU adhesive or approved moisture curing PU adhesive.

    SYSTEM INSTALLATION METHOD:

    • Protan Adhered Roof System - It is required that the roofing membrane is fully adhered (i.e. 100% covered with adhesive). Any insulation must be fastened to the roof structure separately to resist wind forces. This can be achieved by either adhering the insulation to a load bearing surface or mechanically fastening it to the structure. It is critical that there is good 'anchoring' between all the layers in the roof structure.

    Please contact Protan for further advice.

    INSULATION:

    Various types of insulation can be used in combination with Protan membranes and can be flat insulation or sloped insulation. The material type and design will depend on the building design, fire classification and local regulation requirements.

    • Mineral wool (MW) – can be glass or stone type - glass tissue faced
    • Polyisocyanurate (PIR) - glass tissue faced

    INSULATION ADHESIVE:

    • Protan Insulation adhesive or approved insulation manufacturer adhesive 

    VAPOUR CONTROL LAYER:

    • Polyethylene - only use when mechanically fastening the insulation
    • Bitumen

    CONCRETE SUBSTRATE:

    • Structural concrete as either precast elements or reinforced cast in-situ.
    Specification
    • TECHNICAL SPECIFICATION

      Protan EX-A specifications are subject to availability and may not be available or approved in all countries/regions.

      Membrane thickness:

      • 1.5 mm + polyester fleece
      • 1.8 mm + polyester fleece

      Membrane standard widths: 

      • 2.0 m

      Membrane standard roll lengths: 

      • 20 m for thickness 1.5 mm 
      • 15 m for thickness 1.8 mm

      Membrane colours (nearest RAL code):

      • Dark grey F94 - RAL 7012 
      • Light grey F91- RAL 7040
      • Copper green F41 - RAL 6021
      • Red F12 - RAL 3013
      • White/Cool Roof F01- RAL 9003-9016
      • Black FX9- RAL 9004

      FIRE CLASSIFICATION

      Protan EX-A exposed roof systems are classified according to EN 13501-5. Fire classifications are available on a variety of constructions and insulation types. Please contact Protan for further information or refer to the relevant technical approvals.

    Technical specification
    • Unique ref.adhered_concrete_eu
    • Product familyRoofing
    • Product groupSingle Ply Membrane
    • TypeObject (single object)
    • Date of publishing2019-02-19
    • Edition number1
    Related
    • Material mainPVC
    • Material secondaryInsulation
    • Designed inNorway
    • Manufactured inNorway
    Classification
    • BIMobject CategoryConstruction Materials - Waterproofing & Membranes
    • IFC classificationRoof
    • UNSPSC nameRoofing membranes
    • UNSPSC code30151505
    • Uniclass 2015 CodeSs_30_40_30_80
    • Uniclass 2015 DescriptionSingle layer sheet warm roof covering systems
    • CSI MasterFormat 2014 Code07 50 00
    • CSI MasterFormat 2014 TitleMembrane Roofing
    • OmniClass Number23-13 39 31 11 27
    • OmniClass TitlePolyvinyl chloride (PVC) Single Layer Roof Membranes
    • CSI UniFormat II CodeB3010
    • CSI UniFormat II TitleRoof Coverings

    Region availability

    Europe Asia
    Åland Islands
    Türkiye
    Albania
    Andorra
    Austria
    Belarus
    Belgium
    Bosnia and Herzegovina
    Bulgaria
    Croatia
    Cyprus
    Czech Republic
    Denmark
    Estonia
    Faroe Islands
    Finland
    France
    Germany
    Gibraltar
    Greece
    Guernsey
    Hungary
    Iceland
    Ireland
    Isle of Man
    Italy
    Jersey
    Latvia
    Liechtenstein
    Lithuania
    Luxembourg
    Malta
    Moldova
    Monaco
    Montenegro
    Netherlands
    North Macedonia
    Norway
    Poland
    Portugal
    Romania
    Russia
    San Marino
    Serbia
    Slovakia
    Slovenia
    Spain
    Svalbard and Jan Mayen
    Sweden
    Switzerland
    Ukraine
    United Kingdom
    Vatican City