Publish your products
KM I-CHAR 22 SOLVENT-BASED INTUMESCENT PAINTS  FOR THE FIRE PROTECTION OF  STEEL STRUCTURES

KM I-CHAR 22 SOLVENT-BASED INTUMESCENT PAINTS FOR THE FIRE PROTECTION OF STEEL STRUCTURES

KM I-CHAR 22 is used for the fire protection of steel structures, concrete, reinforced concrete,

compartmentation masonries in brick or concrete and in other fields of application.

It guarantees a class of fire resistance up to 2 hours.

KM I-CHAR 22 is an high performances solvent-based intumescent paint. The active solids, the strength of

the intumescent foam with excellent working capacity guarantee an efficient fire barrier.

The fast development of a stable carbon foam with low coefficient of heat transmission guarantees an

efficient protection of the flammable and inflammable substrates.

The solvent-based KM I-CHAR 22 guarantees many advantages of application in difficult environmental

conditions, low temperatures, high humidity and resistance against rain.

Specification
  • KM I-CHAR 22 is used for the fire protection of steel structures, concrete, reinforced concrete,

    compartmentation masonries in brick or concrete and in other fields of application.

    It guarantees a class of fire resistance up to 2 hours.

    KM I-CHAR 22 is an high performances solvent-based intumescent paint. The active solids, the strength of

    the intumescent foam with excellent working capacity guarantee an efficient fire barrier.

    The fast development of a stable carbon foam with low coefficient of heat transmission guarantees an

    efficient protection of the flammable and inflammable substrates.

    The solvent-based KM I-CHAR 22 guarantees many advantages of application in difficult environmental

    conditions, low temperatures, high humidity and resistance against rain.

    (Intumescence is the “swelling during carbonization”).

    Special chemical compounds react with temperature exceeding 200°C, forming a low density foam of

    volume up to 100 times the original mixture. This foam guarantees an efficient barrier against the heat

    transmission, protecting the substrate.

    The fire resistance of the structures are very important for the security in case of blaze. In case of fire in

    buildings, factories, hotels, airports, malls, schools, hospitals, cinema, theaters, multilevel carparks etc., the

    intumescent paints increase the strength of the structures, and they allow to save lives, preserving the

    structure, to allow the carrying of the occupants and the working of firemen.

    USE AND APPLICATION

    An adequate preparation (cleaning, degreasing and removal of fine particles) is necessary.

    The steel surfaces are normally sandblasted (SA21 ½), before applying an anticorrosive primer.

    Two hands of paints are at least to apply by airless systems, by crossing wet-on-wet.

    A typical application of 1,5 mm (dry product)=2,7 kg/ m2

    (wet product) is made by two hands with a wet

    layer 1 mm thick.

    A right equipment is an airless piston pump, minimum compression ratio =40:1, minimum pression 150 bar

    (for example GRACO MARK V or WAGNER ProSpray PS34), self-cleaning nozzle Reverse-A-Clean, nozzle

    diameter 45-50 mils = 1 mm, flexible feed hose of 3/8“ and maximum 30 m long. In the normal spry

    applications, the medium volume flow changes between 3 and 6 l/min.

    All filters of the equipment should be removed after every operating.

    The application may be also done by brush or roller, with long single coats, without brushing. The

    brush/roller application will require more hands than the airless one.

    During the application and the drying you will have to work under appropriate environmental conditions. 

    DATA SHEET

    PRIMER AND RACCOMENDED FINISHES

    KM I-PRIMER 036: Fast drying phenolic modification alchidic primer for steel and galvanized steel.

    Different commercial primers are compatible. Our technical department may provide a list.

    KM I-CHAR 22 is compatible with alchidic systems.

    A better appearance and a less grip of dirt can be obtained by a finishing.

    The intumescent paints can’t be used in the presence of condensation or rain, in wet environments and

    outdoor. Waterproof finishes are necessary.

    Any finishing isn’t generally required indoor according ETAG 018, class Z1 and Z2. Our acryilic waterbased

    paint IDROSOL is used on semi-exposed environments according to ETAG 018, class Y. Our bicomponent

    polyurethanic solvent-based PURETHAN is used on outside and totally exposed according to ETAG 018,

    class X or ISO 12944, corrosion class C3. The application must be particularly careful.

    TECHNICAL SPECIFICATIONS

    Density: 1.35 ± 0,05 kg/dm3

    at 20°C

    Dry Residue: 80% ± 5%w/w - 73% ± 5%v/v

    Colour: white

    Packaging: bucket of 25 kg

    Deadline: 12 months in original packaging and appropriate

    environment

    Performance: 0,55 ± 0,05mm

    Thickness of drying layer (DFT), 1kg/m2

    wet (theoretical)

    Application: normal by airless spray. On the little surfaces and retouching by

    brush or roller

    Wet thickness of one hand: airless spray: max 1300 µm (750 µm DFT)

    Brush and roller: max 500 µm (300 µm DFT)

    Dilution: not recommended. With 5% water-solution, where necessary

    Drying *: 4 h to the touch/ 24 h - complete

    Min. Application Temperature: +0°C

    Max. Application Temperature: +40°C

    (*) @ +20°C at 60% UR. The drying time dipends on thickness, temperature, and relative moisture.

    CERTIFICATIONS AND APPROVALS

    KM I-CHAR 22 is certified according to European and other Standards .

    The characteristics of fire protection for steel structures are certified according to EN 13381-4 and

    EN 13501-2. We have tests report of fire reaction according to EN13501-1 and other special applications.

    The technical specifications have only an information value and the maximal results are guaranteed only after preliminary tests of application.

Technical specification
  • Unique ref.km-i-char-22-solvent-based-intumescent-paints-for-the-fire-protection-of-steel-structures
  • Product familyBuilding Materials
  • Product groupIntumescent paint
  • TypeBuilding Materials
  • Date of publishing2021-08-12
  • Edition number1
Related
  • Material mainPaint
  • Material secondaryOther
  • Designed inItaly
  • Manufactured inItaly
  • Weight Net (Kg)25
Classification
  • BIMobject CategoryConstruction Materials - Paint, Varnishes & Finishes
  • IFC classificationSurface
  • ETIM CodeEG000056
  • ETIM NameFire protection systems
  • UNSPSC nameFinishing materials and products
  • UNSPSC code301519
  • Uniclass 2015 CodePr_35_31_22_15
  • Uniclass 2015 DescriptionConcrete finishing coats
  • CSI MasterFormat 2014 Code09 00 00
  • CSI MasterFormat 2014 TitleFinishes
  • OmniClass Number23-15 21 11 11 11
  • OmniClass TitleSolvent Based General Purpose Paints and Varnishes
  • CSI UniFormat II CodeC3010
  • CSI UniFormat II TitleWall Finishes

Region availability

Europe Asia North America Africa South America Oceania
Åland Islands
Afghanistan
Anguilla
Algeria
Argentina
American Samoa
Albania
Armenia
Antigua and Barbuda
Angola
Bolivia
Australia
Andorra
Azerbaijan
Aruba
Benin
Brazil
Cook Islands
Austria
Bahrain
Barbados
Botswana
Chile
Federated States of Micronesia
Belarus
Bangladesh
Belize
Burkina Faso
Colombia
Fiji
Belgium
Bhutan
Bermuda
Burundi
Ecuador
French Polynesia
Bosnia and Herzegovina
British Indian Ocean Territory
British Virgin Islands
Cameroon
Falkland Islands (Islas Malvinas)
Guam
Bulgaria
Brunei
Canada
Cape Verde
French Guiana
Kiribati
Croatia
Cambodia
Caribbean Netherlands
Central African Republic
Guyana
Marshall Islands
Cyprus
China
Cayman Islands
Chad
Paraguay
Nauru
Czech Republic
Christmas Island
Collectivity of Saint Martin
Comoros
Peru
New Caledonia
Denmark
Cocos (Keeling) Islands
Costa Rica
Côte d'Ivoire
Suriname
New Zealand
Estonia
Georgia
Cuba
Democratic Republic of the Congo
Uruguay
Niue
Faroe Islands
Hong Kong
Curaçao
Djibouti
Venezuela
Norfolk Island
Finland
India
Dominica
Egypt
Northern Mariana Islands
France
Indonesia
Dominican Republic
Equatorial Guinea
Palau
Germany
Iran
El Salvador
Eritrea
Papua New Guinea
Gibraltar
Iraq
Greenland
Eswatini
Pitcairn Islands
Greece
Israel
Grenada
Ethiopia
Samoa
Guernsey
Japan
Guadeloupe
Gabon
Solomon Islands
Hungary
Jordan
Guatemala
Ghana
Timor-Leste
Iceland
Kazakhstan
Haiti
Guinea
Tokelau
Ireland
Kuwait
Honduras
Guinea-Bissau
Tonga
Isle of Man
Kyrgyzstan
Jamaica
Kenya
Tuvalu
Italy
Laos
Martinique
Lesotho
United States Minor Outlying Islands
Jersey
Lebanon
Mexico
Liberia
Vanuatu
Latvia
Macau
Montserrat
Libya
Wallis and Futuna
Liechtenstein
Malaysia
Nicaragua
Madagascar
Lithuania
Maldives
Panama
Malawi
Luxembourg
Mongolia
Puerto Rico
Mali
Malta
Myanmar (Burma)
Saint Kitts and Nevis
Mauritania
Moldova
Nepal
Saint Lucia
Mauritius
Monaco
North Korea
Saint Pierre and Miquelon
Mayotte
Montenegro
Oman
Saint Vincent and the Grenadines
Morocco
Netherlands
Pakistan
Saint-Barthélemy
Mozambique
North Macedonia
Palestine
Sint Maarten
Namibia
Norway
Philippines
The Bahamas
Niger
Poland
Qatar
Trinidad and Tobago
Nigeria
Portugal
Saudi Arabia
Turks and Caicos Islands
Republic of the Congo
Romania
Singapore
U.S. Virgin Islands
Reunion
Russia
South Korea
United States
Rwanda
San Marino
Sri Lanka
Saint Helena
Serbia
Syria
São Tomé and Príncipe
Slovakia
Taiwan
Senegal
Slovenia
Tajikistan
Seychelles
Spain
Thailand
Sierra Leone
Svalbard and Jan Mayen
Türkiye
Somalia
Sweden
Turkmenistan
South Africa
Switzerland
United Arab Emirates
South Sudan
Ukraine
Uzbekistan
Sudan
United Kingdom
Vietnam
Tanzania
Vatican City
Yemen
The Gambia
Togo
Tunisia
Uganda
Western Sahara
Zambia
Zimbabwe