Basic eConnect® PDU
Basic eConnect® PDU
Basic eConnect® PDU

    Basic eConnect® PDU

    Basic eConnect® PDUs provide reliable power distribution in high-density applications where no power monitoring is required.

    Key Features and Benefits

    Resistance to High Temperature – Market-leading temperature ratings of up to 149°F (65°C) ensures reliability when mounted toward hot aisles 

    Simplified Load Balancing – Phase-balance outlets on three-phase models ensure equal loading across all phases; allows use of shorter equipment power cords for better cable and airflow management 

    No Accidental Disconnections – Patent-pending, low-profile locking outlets prevent accidental disconnections without requiring special cords 

    Easy Identification of Failover Unit – Redundancy Pack includes 2 PDUs (one in Black and one in Glacier White) for easy identification of the primary and secondary unit 

    Latest UL Compliance – Meets UL and IEC 62368 for compliance with new listing requirements for North America and the European Union 

    Cabinet Preinstallation – Complete ecosystem ships ready for IT equipment integration. Saves deployment time and reduces packaging waste

      Additional Features:

      • Breaker and outlet groups are color-coded in multi-breaker units for easy identification
      • Universal tool-less mounting features
      • Customization capabilities: outlet configurations, color options, power cord length, input connection types and more
      • Made in the United States, TAA-compliant

      Specification
      • Description: Single-input, vertical rack-mount PDUs

        Use: For indoors or within enclosures, in environmentally controlled areas, may not be used outdoors or in harsh environments

        Refer to Operating Conditions listed below

        Power Input: 

          • Alternating current, 50/60 Hz, 10’ (3m) input power cord

          • Voltage, maximum current, and inlet/plug type varies per model (see ordering table)

        Power Capacity: Specific to PDU, limited by circuit breakers or power input (see ordering table)

        Power Output: NEMA 5-20R, Locking IEC C13 and/or IEC C19 Outlets, specific to PDU with up to 54 outlets (see order table)

        Circuit Protection:

          • UL 489 listed, single- or two-pole, 100%-rated hydraulic-magnetic breakers available on single- and three-phase models  with 30A and above input

          • 10kAIC breakers on 220-240/380-415 VAC models; 5kAIC for all other models

          • Low-profile design prevents accidental discharge

        Mounting: • 2 preinstalled toolless mounting buttons; adjustable positions

          • Top or bottom power cord entry orientation

        Grounding/Bonding: 

          • Bonded power inlet/plug and external bond connection with a threaded M5 attachment point

          • Includes a bonding kit for CPI cabinets

        Color Options: • Black or Glacier White

          • Redundancy Pack includes (1) Black PDU and (1) Glacier White PDU

        Operating Conditions:

          • Temperature: 32°F – 149°F (0°C – 65°C) at Input Power Rating (kW)

          • Relative Humidity: 5% – 95%, non-condensing

          • Elevation: 0 – 10,000 ft (0 – 3,000 m)

        Storage/Non-operating

        Conditions:

        Temperature: -13°F – 149°F (-25°C – 65°C)

          • Relative Humidity: 5% – 95%, noncondensing

          • Elevation: 0 – 50,000 ft (0 – 15,000 m)

        Shipping Weight: 27 lb (12 kg) single unit; 54 lb (24 kg) Redundancy Pack

        Certifications: UL/cUL/IEC62368, CE (EU), FCC Part 15, Class A, EN 55022, RoHS Compliant

        Warranty: 3 years standard with advanced replacement; 2 additional years optional

      Technical specification
      • Unique ref.cpi-basic-pdu
      • Product familyComputer Network Equipment
      • Product groupPower Management
      • TypeObject (single object)
      • Date of publishing2020-03-26
      • Edition number1
      Related
      • Material mainPlastic
      • Designed inUnited States
      • Manufactured inUnited States
      Classification
      • BIMobject CategoryElectrical - Distribution
      • IFC classificationElectric Distribution
      • ETIM CodeEC002762
      • ETIM NamePower distribution unit (PDU)
      • UNSPSC namePower distribution units PDUs
      • UNSPSC code39121017
      • CSI MasterFormat 2014 Code26 26 00
      • CSI MasterFormat 2014 TitlePower Distribution Units
      • OmniClass Number23-35 31 00
      • OmniClass TitleElectrical Power Distribution Devices
      • CSI UniFormat II CodeD5010
      • CSI UniFormat II TitleElectrical Service and Distribution

      Region availability

      Europe Asia North America Africa South America Oceania
      Åland Islands
      Afghanistan
      Anguilla
      Algeria
      Argentina
      American Samoa
      Albania
      Armenia
      Antigua and Barbuda
      Angola
      Bolivia
      Australia
      Andorra
      Azerbaijan
      Aruba
      Benin
      Brazil
      Cook Islands
      Austria
      Bahrain
      Barbados
      Botswana
      Chile
      Federated States of Micronesia
      Belarus
      Bangladesh
      Belize
      Burkina Faso
      Colombia
      Fiji
      Belgium
      Bhutan
      Bermuda
      Burundi
      Ecuador
      French Polynesia
      Bosnia and Herzegovina
      British Indian Ocean Territory
      British Virgin Islands
      Cameroon
      Falkland Islands (Islas Malvinas)
      Guam
      Bulgaria
      Brunei
      Canada
      Cape Verde
      French Guiana
      Kiribati
      Croatia
      Cambodia
      Caribbean Netherlands
      Central African Republic
      Guyana
      Marshall Islands
      Cyprus
      China
      Cayman Islands
      Chad
      Paraguay
      Nauru
      Czech Republic
      Christmas Island
      Collectivity of Saint Martin
      Comoros
      Peru
      New Caledonia
      Denmark
      Cocos (Keeling) Islands
      Costa Rica
      Côte d'Ivoire
      Suriname
      New Zealand
      Estonia
      Georgia
      Cuba
      Democratic Republic of the Congo
      Uruguay
      Niue
      Faroe Islands
      Hong Kong
      Curaçao
      Djibouti
      Venezuela
      Norfolk Island
      Finland
      India
      Dominica
      Egypt
      Northern Mariana Islands
      France
      Indonesia
      Dominican Republic
      Equatorial Guinea
      Palau
      Germany
      Iran
      El Salvador
      Eritrea
      Papua New Guinea
      Gibraltar
      Iraq
      Greenland
      Eswatini
      Pitcairn Islands
      Greece
      Israel
      Grenada
      Ethiopia
      Samoa
      Guernsey
      Japan
      Guadeloupe
      Gabon
      Solomon Islands
      Hungary
      Jordan
      Guatemala
      Ghana
      Timor-Leste
      Iceland
      Kazakhstan
      Haiti
      Guinea
      Tokelau
      Ireland
      Kuwait
      Honduras
      Guinea-Bissau
      Tonga
      Isle of Man
      Kyrgyzstan
      Jamaica
      Kenya
      Tuvalu
      Italy
      Laos
      Martinique
      Lesotho
      United States Minor Outlying Islands
      Jersey
      Lebanon
      Mexico
      Liberia
      Vanuatu
      Latvia
      Macau
      Montserrat
      Libya
      Wallis and Futuna
      Liechtenstein
      Malaysia
      Nicaragua
      Madagascar
      Lithuania
      Maldives
      Panama
      Malawi
      Luxembourg
      Mongolia
      Puerto Rico
      Mali
      Malta
      Myanmar (Burma)
      Saint Kitts and Nevis
      Mauritania
      Moldova
      Nepal
      Saint Lucia
      Mauritius
      Monaco
      North Korea
      Saint Pierre and Miquelon
      Mayotte
      Montenegro
      Oman
      Saint Vincent and the Grenadines
      Morocco
      Netherlands
      Pakistan
      Saint-Barthélemy
      Mozambique
      North Macedonia
      Palestine
      Sint Maarten
      Namibia
      Norway
      Philippines
      The Bahamas
      Niger
      Poland
      Qatar
      Trinidad and Tobago
      Nigeria
      Portugal
      Saudi Arabia
      Turks and Caicos Islands
      Republic of the Congo
      Romania
      Singapore
      U.S. Virgin Islands
      Reunion
      Russia
      South Korea
      United States
      Rwanda
      San Marino
      Sri Lanka
      Saint Helena
      Serbia
      Syria
      São Tomé and Príncipe
      Slovakia
      Taiwan
      Senegal
      Slovenia
      Tajikistan
      Seychelles
      Spain
      Thailand
      Sierra Leone
      Svalbard and Jan Mayen
      Türkiye
      Somalia
      Sweden
      Turkmenistan
      South Africa
      Switzerland
      United Arab Emirates
      South Sudan
      Ukraine
      Uzbekistan
      Sudan
      United Kingdom
      Vietnam
      Tanzania
      Vatican City
      Yemen
      The Gambia
      Togo
      Tunisia
      Uganda
      Western Sahara
      Zambia
      Zimbabwe