    COLLECTanDRAIN Model 5450 Self-Maintaining Auxiliary Drain

    The COLLECTanDRAIN® Model 5450 Series of auxiliary drains feature a traditionally configured condensation collection assembly contained inside an insulated and heated cabinet. By incorporating a unique, self-maintaining design the Model 5450 offers more than just freeze protection. This feature prevents the auxiliary drain from filling beyond the safety level of the heated cabinet and automatically sheds condensation from the collection assembly when the level reaches approximately 80%. Any additional accumulation will flow into a drain trap that allows the excess to automatically drain from the system while maintaining the integrity of the dry valve. The easily mounted, lockable, steel cabinet is finished in a highly-visible, red, powder coat that includes appropriate identification signage and can be wired to the fire panel for remote notification. The Model 5450 is designed for installation in climates where freezing or below freezing temperatures are present and result in the failure of typical collectors. The Model 5450 maintains a comfortable temperature above freezing while minimizing power consumption. Available with galvanized or black steel and an optional Hot Operation Trouble (HOT) Monitor.

    Model 5450A has galvanized piping and model 5450B includes black steel piping.

    Model 5450H includes the hot operation trouble (HOT) monitor to send notifications if there is a heater issue. The Hot Operation Trouble (HOT) monitor tracks the heater's on/off cycles and compares that information against its own internal thermostat to make sure the heater is performing correctly. For example, if the cabinet door is accidentally left open causing the heater to run continuously, the HOT monitor will trip the local audible and visual alarms and alert the fire control panel. It will also trigger a notification if it detects that the heater is not operating enough to keep the interior temperature safely above freezing.

    Specification
    • Model 5450 COLLECTANDRAIN

      2.1 DRY-PIPE SYSTEM AUXILIARY DRAIN

      Auxiliary Drain and Condensation Collecting Assemblies for Dry Pipe and Preaction Sprinkler Systems shall be installed in order to provide for complete system drainage. Where the trapped capacity of an isolated section of system piping exceeds 5 gallons an auxiliary drain shall be provided. The auxiliary drain shall be installed in an accessible location and be capable of collecting and removing moisture from the system while minimizing the potential for excessive loss of air pressure and possible unplanned operation of the dry pipe valve. The Auxiliary Drains shall meet the following requirements:

      1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the work include, but are not limited to, the following:
        1. AGF Manufacturing Inc.; Model 5450 COLLECTANDRAIN™.
        2. <Insert manufacturer's name>.
      2. Standards:
        1. NFPA 13.
        2. NFPA 25.
      3. Components:
        1. Cabinet: A secure locking, red powder-coated, insulated cabinet with required signage adhering to NFPA guidelines.
        2. Heating Element: Temperature-sensitive internal heating element to prevent excess condensation in the drum drip from freezing.
        3. Float Switch: Activates an audible alarm and visual signal to notify when the auxiliary drain requires maintenance.
        4. System Alarm Test Button: An integral TEST button allows for system testing.
        5. Thermometer: Externally mounted for easy monitoring of temperature conditions inside the cabinet.
        6. Drain Assembly:
          1. Two 1 inch by 2 inches (25 mm by 51 mm) Bell Reducers.
          2. 2 inch by 12 inches long (51 mm by 305 mm) Condensate Nipple.
          3. 1 inch (25 mm) Galvanized Square Head Plug.
          4. Two 1 inch (25 mm) MIPT x FIPT Brass quarter-turn ball valves with chrome-plated balls.
          5. Ancillary drain with Y strainer to shed accumulated water when the auxiliary drain reaches approximately 80% full.
          6. Mounting hardware.
          7. Each unit is fully assembled and ready to be attached to dry pipe systems using galvanized or black piping components and 1-inch brass quarter-turn ball valves with chrome-plated brass balls.
    • 4. Product: Model 5450A. Cabinet with Galvanized Auxiliary Drain, Heater, and Ancillary Drain.
    • 5. Product: Model 5450B. Cabinet with Black Steel Pipe Auxiliary Drain, Heater, and Ancillary Drain.
    • 6. Product: Model 5450H. Cabinet with Galvanized Auxiliary Drain, Heater, Ancillary Drain, and Hot Operation Trouble Monitor.
    • 7. Product: Model 5680A. All-Weather Cover for Exposed Locations.
    Technical specification
    • Unique ref.agf-model-5450
    • Product familyAGF Fire Sprinkler Products
    • Product groupCOLLECTanDRAIN
    • TypeObject (single object)
    • Date of publishing2022-03-03
    • Edition number1
    • Height (inches)36
    • Width (inches)18
    • Depth (inches)12
    Related
    • Material mainGalvanized steel
    • Material secondaryPowder coated steel
    • Designed inUnited States
    • Manufactured inUnited States
    • Weight Net (Lbs)66
    Classification
    • BIMobject CategoryFire Products - Sprinkler Systems
    • IFC classificationValve
    • ETIM CodeEG000056
    • ETIM NameFire protection systems
    • UNSPSC nameFire sprinkler systems
    • UNSPSC code46191602
    • CSI MasterFormat 2014 Code21 00 00
    • CSI MasterFormat 2014 TitleFire Suppression
    • OmniClass Number23-29 33 00
    • OmniClass TitleFire Suppression System Components
    • CSI UniFormat II CodeD40
    • CSI UniFormat II TitleFIRE PROTECTION

    Region availability

    Asia Europe Africa South America Oceania North America
    Afghanistan
    Albania
    Algeria
    Argentina
    Australia
    Belize
    Armenia
    Austria
    Angola
    Bolivia
    Fiji
    Canada
    Azerbaijan
    Belarus
    Benin
    Brazil
    New Caledonia
    Costa Rica
    Bangladesh
    Belgium
    Botswana
    Chile
    New Zealand
    Cuba
    Bhutan
    Bosnia and Herzegovina
    Burkina Faso
    Colombia
    Papua New Guinea
    Dominican Republic
    Cambodia
    Bulgaria
    Burundi
    Ecuador
    Solomon Islands
    El Salvador
    China
    Croatia
    Cameroon
    Falkland Islands (Islas Malvinas)
    Timor-Leste
    Greenland
    Georgia
    Cyprus
    Central African Republic
    French Guiana
    Vanuatu
    Guatemala
    India
    Czech Republic
    Chad
    Guyana
    Haiti
    Indonesia
    Denmark
    Côte d'Ivoire
    Paraguay
    Honduras
    Iran
    Estonia
    Democratic Republic of the Congo
    Peru
    Jamaica
    Iraq
    Finland
    Djibouti
    Suriname
    Mexico
    Israel
    France
    Egypt
    Uruguay
    Nicaragua
    Japan
    Germany
    Equatorial Guinea
    Venezuela
    Panama
    Jordan
    Greece
    Eritrea
    Puerto Rico
    Kazakhstan
    Hungary
    Eswatini
    The Bahamas
    Kuwait
    Iceland
    Ethiopia
    United States
    Kyrgyzstan
    Ireland
    Gabon
    Laos
    Italy
    Ghana
    Lebanon
    Latvia
    Guinea
    Malaysia
    Lithuania
    Guinea-Bissau
    Mongolia
    Luxembourg
    Kenya
    Myanmar (Burma)
    Moldova
    Lesotho
    Nepal
    Montenegro
    Liberia
    North Korea
    Netherlands
    Libya
    Oman
    North Macedonia
    Madagascar
    Pakistan
    Norway
    Malawi
    Palestine
    Poland
    Mali
    Philippines
    Portugal
    Mauritania
    Qatar
    Romania
    Morocco
    Saudi Arabia
    Russia
    Mozambique
    South Korea
    Serbia
    Namibia
    Sri Lanka
    Slovakia
    Niger
    Syria
    Slovenia
    Nigeria
    Taiwan
    Spain
    Republic of the Congo
    Tajikistan
    Svalbard and Jan Mayen
    Rwanda
    Thailand
    Sweden
    Senegal
    Türkiye
    Switzerland
    Sierra Leone
    Turkmenistan
    Ukraine
    Somalia
    United Arab Emirates
    United Kingdom
    South Africa
    Uzbekistan
    South Sudan
    Vietnam
    Sudan
    Yemen
    Tanzania
    The Gambia
    Togo
    Tunisia
    Uganda
    Western Sahara
    Zambia
    Zimbabwe