Publish your products
Boulevard Planters
Boulevard Planters
Boulevard Planters
Boulevard Planters
    Tournesol

    Boulevard Planters

    Boulevard Planters Rectangle & Square

    Boulevard commercial-grade planters combine the durability of fiberglass with the warmth of wood. A fiberglass liner keeps moisture from soil, ground, and irrigation away from the cladding extending the life and beauty of the wood surfaces.

  • Commercial-grade planters
  • Suitable for indoor or outdoor use
  • Fiberglass liner with wood cladding
  • 1-5/8” drain holes available upon request
  • A broad range of standard sizes
  • Over 100 sizes are available. 

    Specification
    • Guide Specification

      Section 129300 Site Furnishings
      Section 129200 Planters

      Tournesol Siteworks Boulevard Wood-Clad Planters

      1.0 GENERAL

      1.1 WORK INCLUDED

      A. Provision of wood and steel planters

      1.2 RELATED WORK

      A. Section 033000 Cast-in-Place concrete
      B. Section 061000 Rough Carpentry
      C. Section 062000 Finish Carpentry

      1.3 SUBMITTALS

      A. Product Data: Manufacturer's standard catalog cut sheets.
      B. Samples: As required for color selection or material thickness only.
      C. Shop Drawings: For custom applications, showing critical sizes and dimensions for installation and integration with other work.

      1.4 DELIVERY, STORAGE AND HANDLING

      A. Unwrap & inspect planters after delivery for signs of damage during transit.
      B. Protect planters from damage during storage and handling.
      C. Store planters indoors if possible. Unwrapped planters exposed to sunlight may begin patina process, even with treatment applied. Do not stack planters.

      1.5 PROJECT CONDITIONS

      A. Contractor to provide adequate structural support for planters.
      B. Protect units from damage by adjacent work.

      1.6 REFERENCES

      A. American Wood Protection Association (AWPA)
      Guidance Document N – Data Requirements for Listing Thermally Modified Wood
      Standard U1 - Use Category System: User Specification for Treated Wood
      Standard E1- Method for Laboratory Evaluation to Determine Resistance to Subterranean Termites
      Standard E7 - Method of Evaluating Wood Preservatives by Field Tests with Stakes
      Standard E9 - Field Test for the Evaluation of Wood Preservatives to be Used in Non-Soil Contact
      Standard E10 - Method of Testing Wood Preservatives by Laboratory Soil-Block Cultures
      Standard E12 - Method of Determining Corrosion of Metal in Contact with Treated Wood
      Standard E14 - Method of Evaluating Wood Preservatives in a Soil Bed
      Standard E21 - Test Method for the Evaluation of Preservative Treatments for Lumber and Timbers Against Subterranean Termites in Above-Ground, Protected Applications
      B. American Society for Testing and Materials (ASTM)
      ASTM D5664 - Standard Test Method for Evaluating the Effects of Fire-Retardant Treatments and Elevated Temperatures on Strength Properties of Fire-Retardant Treated Lumber
      ASTM D3201 - Standard Test Method for Hygroscopic Properties of Fire-Retardant Wood and Wood-Based Products
      ASTM E1354 - Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

      2.0 PRODUCTS

      2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS

      A. Boulevard Planters, manufactured by Tournesol Siteworks LLC. 2930 Faber St., Union City, CA 94587 Tournesol.com
      Tel: (800) 542-2282 FAX (510) 471-6243

      2.2 BOULEVARD PLANTERS

      A. Materials

      1. Lumber shall be manufactured from Boulevard thermally-modified wood, conforming to AWPA Use-Class UC3B, Above Ground, Exposed (see AWPA Guidance N for required tests). Manufacturer should provide documentation of the quality processes used during thermal modification. Base woods shall be Oak. Wood shall be sourced & processed entirely in the U.S. Other lumber available if specified.

      2. Powdercoated carbon steel corner structure – ASTM A36 hot rolled steel structure.

      3. Liner – All parts shall be constructed of glass fiber reinforced polyester resin, using either the hand-layup or spray-layup methods.
      a. Glass fibers shall be PPG or equivalent. For hand layup fibers should be uniform chopped strand mat, minimum 3 oz. density. Liners must use three layers (or spray equivalent)
      b. Polyester resin shall be compounded by a reputable manufacturer. All planters and planter liners will be fabricated of 100% resin – inorganic fillers will not be acceptable.

      4. Hardware – Stainless steel grade 18-8 wood screws, and all bolts, washers, and nuts.
      B. Construction
         1. Lumber – Profiled and/or shaped with minimum surface smoothness of 20 KCPI. No tear-outs or knife-knicks.
         2. Powdercoated Steel Corner Structure – Formed and welded
         3. All hardware to be internal and hidden

      C. Performance characteristics
         1. Lumber – All corners and edges to be rounded or eased. All attachment points to be internal and not visible. Lumber to be treated with Penofin oil prior to delivery to prevent initial weathering. To prevent long-term graying, wood must be periodically retreated.
         2. Powdercoated Steel Corner Structure – All exposed sharp edges removed
         3. Liner – built with bulkheads or gussets and wall reinforcement to prevent wall from flexing when planter is filled with soil.

      D. Finish: specified finish; factory finished.
         1. Boulevard Wood – wood finished with Penofin oil to resist UV weathering. Penofin darkens wood upon application, wood will lighten as the oil evaporates. Reapply treatment yearly for maximum UV protection. If left untreated, wood will patina to natural gray state.
         2. Carbon steel corner structure –
         a. Following fabrication the planter steel frame pieces shall be cleaned and treated with an iron phosphate process prior to the coating application. This process shall include a non-chromated alkaline cleaner, and an iron phosphate treatment, followed with an acidic sealer for maximum adhesion. Corrosion-resistant zinc undercoat shall be applied, 1-2mils thick. The protective powder coat shall be polyester or polyester TGIC powder, a minimum 4 mils thick. Following application parts shall be baked until properly cured.

      E. Sizes: Refer to catalog for standard sizes. Custom sizes as per approved shop drawings.

      2.3 PLANTER OPTIONS

      A. Wood Cladding Options – Depending on placement (against a wall, against one another, etc..), Boulevard planters may not require wood cladding on all sides. Product to be delivered with wood on one-, two-, three-, or all four sides (standard configuration). Specify which side (or combination of sides) should be clad. Note: Planter lengths will be reduced by approx. ¾” for each side unclad. Unclad sides will have a 90deg cladding support to allow the planter to sit closely by the wall or adjacent planter.

      B. Scoop Connectivity – To create the appearance of a continuous planting area, adjacent planters may have their sidewalls lowered. Adjacent planters shall be maximum of three-wall clad units, and shall be delivered with a Scoop hardware kit to prevent water or soil from spilling between units. Holes to attach scoop units to be drilled once planters are in final location and partially filled. Connecting sealant to be silicone, and hardware to be stainless steel.

      C. Alternative material cladding options – Boulevard planters may have steel panels substituted for wood planking for decorative purposes. Steel panels available in a range of standard sizes, see website for details. Panels may also be laser-cut with logos or decorative patterns as required. Panels available in 12ga. brushed stainless steel, weathering steel, or powdercoated mild steel. Cladding panel attachments to be hidden and invisible, and panels to have decorative return and radiused edges to match wood.

      D. Trellis or Privacy Panels – Boulevard planters may be delivered with bracket pockets to accommodate a vertical support for trellis panels or metal privacy screens. See Wilshire and Boulevard Screen page at Tournesol.com.

      3.0 EXECUTION

      3.1 PREPARATION
      A. Prior to fabrication, the contractor shall verify as-built dimensions of area to ensure proper size, fit and quantity required.

      3.2 INSTALLATION
      A. Provide continuous basal support.
      B. Install level.
      C. For scoop connectivity, trellis or privacy panels, follow instructions provided by manufacturer carefully.

    Technical specification
    • Unique ref.boulevard-planters
    • Product familyBoulevard Collection
    • Product groupBoulevard Planters
    • TypeObject (single object)
    • Date of publishing2024-08-02
    • Edition number1
    Related
    • Material mainThermally Modified Wood
    • Material secondaryFiberglass
    • Designed inUnited States
    • Manufactured inUnited States
    Classification
    • BIMobject CategoryLandscaping - Other
    • CSI MasterFormat 2014 Code32 94 33
    • CSI MasterFormat 2014 TitlePlanters
    • OmniClass Number23-11 27 13 17
    • OmniClass TitlePlanters

    Region availability

    Europe North America Asia South America
    Åland Islands
    Anguilla
    Armenia
    Argentina
    Albania
    Antigua and Barbuda
    Azerbaijan
    Bolivia
    Andorra
    Aruba
    Bangladesh
    Brazil
    Austria
    Barbados
    Bhutan
    Chile
    Belarus
    Belize
    British Indian Ocean Territory
    Colombia
    Belgium
    Bermuda
    Brunei
    Ecuador
    Bosnia and Herzegovina
    British Virgin Islands
    Cambodia
    Falkland Islands (Islas Malvinas)
    Bulgaria
    Canada
    China
    French Guiana
    Croatia
    Caribbean Netherlands
    Christmas Island
    Guyana
    Cyprus
    Cayman Islands
    Cocos (Keeling) Islands
    Paraguay
    Czech Republic
    Collectivity of Saint Martin
    Georgia
    Peru
    Denmark
    Costa Rica
    Hong Kong
    Suriname
    Estonia
    Cuba
    India
    Uruguay
    Faroe Islands
    Curaçao
    Indonesia
    Venezuela
    Finland
    Dominica
    Japan
    France
    Dominican Republic
    Kazakhstan
    Germany
    El Salvador
    Kyrgyzstan
    Gibraltar
    Greenland
    Laos
    Greece
    Grenada
    Macau
    Guernsey
    Guadeloupe
    Malaysia
    Hungary
    Guatemala
    Maldives
    Iceland
    Haiti
    Mongolia
    Ireland
    Honduras
    Myanmar (Burma)
    Isle of Man
    Jamaica
    Nepal
    Italy
    Martinique
    North Korea
    Jersey
    Mexico
    Pakistan
    Latvia
    Montserrat
    Philippines
    Liechtenstein
    Nicaragua
    Singapore
    Lithuania
    Panama
    South Korea
    Luxembourg
    Puerto Rico
    Sri Lanka
    Malta
    Saint Kitts and Nevis
    Taiwan
    Moldova
    Saint Lucia
    Tajikistan
    Monaco
    Saint Pierre and Miquelon
    Thailand
    Montenegro
    Saint Vincent and the Grenadines
    Turkmenistan
    Netherlands
    Saint-Barthélemy
    Uzbekistan
    North Macedonia
    Sint Maarten
    Vietnam
    Norway
    The Bahamas
    Poland
    Trinidad and Tobago
    Portugal
    Turks and Caicos Islands
    Romania
    U.S. Virgin Islands
    Russia
    United States
    San Marino
    Serbia
    Slovakia
    Slovenia
    Spain
    Svalbard and Jan Mayen
    Sweden
    Switzerland
    Ukraine
    United Kingdom
    Vatican City