Infrared Vacuum System, Model VS

Infrared Vacuum System, Model VS

The Premier Vacuum Series takes full advantage of the performance synergies that only an engineered system can provide. Unlike other “systems” which merely connect multiple unitary style heaters, this maximum design flexibility ensures that all the performance and energy savings requirements of the application can be realized.
Designs are further enhanced by a full complement of additional features, including diverse tubing materials, reflector shielding configurations, multiple vacuum pump sizes, and advanced control options.

  • Custom engineered to precisely fit your building heat requirements.
  • Vacuum vented for maximum safety and operating efficiency.
  • Burner rates from 60,000 to 250,000 BTU/H can fill any heating need.
  • Up to 1.2 million BTUs on a single vacuum pump with single building penetration.
  • Additional fuel economy of at least 5%.
  • Unique, patented burner design results in - precise firing rates, reduced noxious emissions, shorter tailpipe requirements, more burners in series.
  • Reflectors of superior design and performance with side, bottom, and tilted shield options.
  • Run indicator light.
  • Couplings that outperform all others.
  • Burner housing with no loose service doors.
  • Filters are easily changed even with outside combustion air fitted.
  • Vacuum pumps are corrosion resistant, heavy-duty construction with several sizes available to best match the system.
  • Decorative grills can be installed as an option.
  • Warranty - 1 year for the control panel, 3 years for parts, 10 years for burner head. (For more info; please refer to specs and manual).
  • Patented Technology (US Patent #5,842,854).


Specifikation
  • Low-Intensity infrared Premier Vacuum System VS or VS-VH high efficiency condensing or mid-efficiency non-condensing featuring positioned tuned in-line burners to guarantee the best system efficiency in the industry. Firing rates shall be within the range of 20 MBH to 250 MBH (Model VS shall be 80,000 BTU/HR to 250,000 BTU/HR and Model VS-VH Shall be 20,000 BTU/HR to 120,000 BTU/HR). Burners shall be position-tuned and shall be factory designed to operate in a specific in-line position in the radiant branch to ensure equal firing rates for each burner in the branch. Except for the first burner, subsequent burners in a leg shall have firing rates within +/- 2% of each other. Radiant branches shall contain up to 4 burners in-line on a single branch and must be capable of modulating from 60% to 100% of normal firing rates. Minimum end vent flow rates based on design may not exceed the design provided. End vent flow rates of 200% or more will not be permitted. Assemblies shall be CSA approved to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a negative pressure burner system where exhaust gases and other products of combustion are routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.0 inches W.C. (propane – VS Burners only) and draw no more than 0.2 Amp at 120VAC, 60Hz. Burner head and mounting body shall be cast iron and burner controls shall allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with fewer than 10 surfaces will not be allowed as they allow energy to bounce back to the main heat exchanger tubing. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing and shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall allow fastening of the burner via dual U clamps to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Professional Engineer design showing end vent airflow entry rate as equal as or less than design. 
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with an alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model.
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Teknisk specifikation
  • Unik ref.vs
  • ProduktfamiliePremier Vacuum Series
  • ProduktgruppePremier VS
  • TypeObjekt (enkelt objekt)
  • Udgivelsesdato2021-02-16
  • Udgavenummer1
Relateret
  • Materiale primærtStål
  • Materiale sekundærtAluminium
  • Designet iCanada
  • Fremstillet iCanada
Klassifikation
  • BIMobject-kategoriHVAC - Varmeapparater
  • IFC-klassifikationVarmeapparat
  • UNSPSC-navnSpace heaters
  • UNSPSC-kode40101819
  • Uniclass 2015-kodePr_70_60_36_72
  • Uniclass 2015-beskrivelseRadiant tube heaters
  • CSI MasterFormat 2014-kode23 55 23
  • CSI MasterFormat 2014-titelGas-Fired Radiant Heaters
  • OmniClass-nummer23-33 15 17 13
  • OmniClass-betegnelseFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II-kodeD30
  • CSI UniFormat II-titelHVAC

Tilgængelighed i region

Europa Nordamerika Asien
Åland
Anguilla
Armenien
Albanien
Antigua og Barbuda
Aserbajdsjan
Andorra
Aruba
Bangladesh
Belgien
Bahamas
Bhutan
Bosnien-Herzegovina
Barbados
Brunei Darussalam
Bulgarien
Belize
Cambodia
Cypern
Bermuda
Cocosøerne
Danmark
Canada
Det britiske territorium i Det Indiske Ocean
Estland
Caribbean Netherlands
Filippinerne
Færøerne
Caymanøerne
Georgien
Finland
Costa Rica
Hong Kong
Frankrig
Cuba
Indien
Gibraltar
Curaçao
Indonesien
Grækenland
De britiske jomfruøer
Japan
Guernsey
Dominica
Juleøerne
Holland
Dominikanske Republik
Kazakhstan
Hviderusland
El Salvador
Kina
Irland
Grenada
Kyrgyzstan
Island
Grønland
Laos
Isle of Man
Guadeloupe
Macau
Italien
Guatemala
Malaysia
Jan Mayen
Haiti
Maldiverne
Jersey
Honduras
Mongoliet
Kroatien
Jamaica
Myanmar (Burma)
Letland
Jomfruøerne
Nepal
Liechtenstein
Martinique
Nordkorea
Litauen
Mexico
Pakistan
Luxembourg
Montserrat
Singapore
Malta
Nicaragua
Sri Lanka
Moldova
Panama
Sydkorea
Monaco
Puerto Rico
Taiwan
Montenegro
Saint Kitts og Nevis
Tajikistan
Nordmakedonien
Saint Lucia
Thailand
Norge
Saint Pierre og Miquelon
Turkmenistan
Østrig
Saint Vincent og Grenadinerne
Uzbekistan
Polen
Saint-Barthélemy
Vietnam
Portugal
Saint-Martin
Rumænien
Sint Maarten
Rusland
Trinidad og Tobago
San Marino
Turks- og Caicosøerne
Schweiz
USA
Serbien
Slovakiet
Slovenien
Spanien
Storbritannien
Sverige
Tjekkiet
Tyskland
Ukraine
Ungarn
Vatikanstaten