For Direct Fired Make-Up Air Package Submittal Drawings please click here.
For Direct Fired Make-Up Air Package Performance Data please click here.
Air Volume: 1000 - 21000 cfm Maximum SP: 4" wg. @ standard air density
DIRECT GAS FIRED MAKE-UP AIR
The Direct Gas Fired Make-Up Air package is designed to deliver tempered make-up air for installations requiring frequent air changes. Units are designed for natural and propane gas applications, and for indoor or outdoor installation.
STANDARD FEATURES & BENEFITSG90 galvanized constructionEasy access doorsLifting pointsPre-wired, pre-piped controlsHorizontal or down dischargeVibration isolationHigh efficiency motorsAdjustable drive sheavesFully insulated casingStainless steel burner120 volt control transformer with single point electrical connectionRedundant gas valvesIntermittent spark pilot with timed safety lockoutElectronic flame modulationHigh temperature limit switchAirflow proving switchEconomizer inlet thermostatMotor starterDisconnect switchBurner observation port
AVAILABLE OPTIONSPropane Fuel ApplicationRoom Override ThermostatMotorized Intake DamperRemote control panel including summer/winter switch and operating lightsFreeze Stat with Bypass TimerHi/Low Gas Pressure SwitchesRoom Modulating ThermostatHigh Gas Pressure RegulatorConvenience OutletDX Cooling CoilsEvaporative Cooler IntakeV-Bank Filter IntakeSloped Filter IntakeAuxiliary StartersInlet Gas Pressure GaugeIndoor Hanging CradleVAV PackagesRoof CurbsClogged Filter SwitchCooling Thermostat and InterlockExtra Set of V-Belts
ADDITIONAL FEATURES
The Direct Gas Fired Heater is ETL Listed for use in tempering make-up air. The make-up air is introduced into the heater intake directly from outside the building. Packages are certified to the ANSI Z83.4a-2001/CSA 3.7a-2001 combined safety standard and are available in sizes up to 2,500,000 BTUH and 21,000 CFM. A unique feature of our unit is the patented self-adjusting burner profile plates, which ensure proper air velocity and pressure drop across the burner for clean combustion. Spring-loaded profile plates react to the momentum of the fresh air stream, therefore, no motors or actuators are needed to drive them, nor do they need to be manually set to a specific position. With this feature, all of our units are designed for variable air volume capabilities.
Standard features include intermittent spark ignition system with timed safety lockout and redundant gas valves. Units consist of a galvanized enclosure with an elevated gas burner which burns directly in the air stream. The burner consists of non-clogging, stainless steel combustion baffles attached to a aluminum gas supply section. The burner is capable of 100% thermal efficiency with a maximum turndown ratio of 30 to 1. The burner module has a standard horizontal inlet and discharge duct connection, and is located upstream of the blower module. The blower module has a standard horizontal inlet designed to accommodate an outside air inlet hood with standard 2" filters and screen.
To satisfy a variety of installation requirements, packages are available in a number of configurations which include additions of a v-bank, cooling coil or an evaporative cooler intake module. All modules bolt together to form a rigid common base structure that mounts onto a single curb structure.
Combination packages that include both exhaust and supply fans mounted on a single roof curb are also available, please contact your sales representative for more information.
CERTIFICATIONS
The AD Model has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. and Canadian products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance.
Model AD is ETL Listed under file number J20042560-001 and complies with ANSI Z83.4-Second Edition and CSA 3.7-2006 Standards.