Publikovat produkty
Two Stage Infrared Heater, Model TA

Two Stage Infrared Heater, Model TA

Heavy duty industrial/commercial infrared heater featuring the best overall performance in the industry. All Series T units include Hi-Low output capability which allows quicker recovery on the high fire and economical steady operation on the low fire. 40 MBH to 220 MBH rates available with 100% efficient reflector. Natural Gas or LPG.

  • Two-stage heater – dual output for improved rate differential, 40,000 to 220,000 BTU/h
  • Natural Gas or LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, the burner can run during servicing
  • Self-diagnostic ignition module
  • Parabolic aluminum reflectors – most efficient in the industry
  • Direct spark ignition
  • Vented or unvented
  • Hinged service cover – easy to service
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy-duty couplings – no leaks, cannot be over tightened
  • Operating status lights
  • Low voltage controls
  • Three-year warranty on all components
  • Five-year warranty on hot rolled heat exchanger
  • Seven-year warranty on aluminized heat exchanger with post purge feature
  • 10-year warranty on optional aluminized heat exchanger with post purge feature
  • Post purge


Specifikace
  • Low-Intensity Two Stage Infrared Tube Heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40/30 MBH to 220/165 MBH with a minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. The product shall be (please select model for unique specification) Model TA (sealed blower design), Model TX (enclosed burner design), or Model TXR (enclosed, moisture sealed burner design for rugged, harsh environments or outdoor use) as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks shall be possible with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors shall have a minimum of 10 reflective surfaces.  Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing, and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution most include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model. 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Technická specifikace
  • Jedinečná ref. hodnotata
  • Skupina výrobkůTwo Stage Infrared Heaters
  • Skupina produktůLow Intensity - Series T
  • TypObjekt
  • Datum zveřejnění2021-02-16
  • Číslo vydání1
Související
  • Hlavní materiálOcel
  • Vedlejší materiálHliník
  • Navrženo vKanada
  • Vyrobeno vKanada
Klasifikace
  • Kategorie objektu BIMHVAC - Ohřívače
  • Název UNSPSCTubular heaters
  • Kód UNSPSC40101822
  • Kód Uniclass 2015Pr_70_60_36_72
  • Popis Uniclass 2015Radiant tube heaters
  • Kód CSI MasterFormat 201423 55 23
  • Název CSI MasterFormat 2014Gas-Fired Radiant Heaters
  • Číslo OmniClass23-33 15 17 13
  • Název OmniClassFuel Fired HVAC Radiant Heaters
  • Kód CSI UniFormat IID30
  • Název CSI UniFormat IIHVAC

Dostupnost regionu

Evropa Severní Amerika Asie
Ålandy
Anguilla
Arménie
Albánie
Antigua a Barbuda
Ázerbájdžán
Andorra
Aruba
Bangladéš
Belgie
Bahamy
Bhútán
Bělorusko
Barbados
Britské indickoocenánské území
Bosna a Hercegovina
Belize
Brunej
Bulharsko
Bermudské ostrovy
Čína
Černá Hora
Britské Panenské ostrovy
Filipíny
Česká republika
Curaçao
Gruzie
Chorvatsko
Dominika
Hongkong
Dánsko
Dominikánská republika
Indie
Estonsko
Gaudeloupe
Indonésie
Faerské ostrovy
Grenada
Japonsko
Finsko
Grónsko
Kambodža
Francie
Guatemala
Kazachstán
Gibraltar
Haiti
Kokosové ostrovy
Guernsey
Honduras
Korejská lidově demokratická republika
Irsko
Jamajka
Korejská republika
Island
Kajmanské ostrovy
Kyrgyzstán
Itálie
Kanada
Laos
Jan Mayen
Karibské Nizozemsko
Macao
Jersey
Kostarika
Malajsie
Kypr
Kuba
Maledivy
Lichtenštejnsko
Martinik
Mongolsko
Litva
Mexiko
Myanmar (Barma)
Lotyšsko
Montserrat
Nepál
Lucembursko
Nikaragua
Pákistán
Maďarsko
ostrovy Turks a Caicos
Singapur
Malta
Panama
Šrí Lanka
Moldavsko
Pannenske Ostrovy
Tádžikistán
Monako
Portoriko
Tchaj-wan
Německo
Saint-Pierre a Miquelon
Thajsko
Nizozemsko
Salvador
Turkmenistán
Norsko
Spojené státy americké
Uzbekistán
ostrov Man
Svatá Lucie
Vánoční ostrov
Polsko
Svatý Bartoloměj
Vietnam
Portugalsko
Svatý Kryštof a Nevis
Rakousko
Svatý Martin
Řecko
Svatý Martin
Rumunsko
Svatý Vincenc a Grenadiny
Rusko
Trinidad a Tobago
San Marino
Severní Makedonie
Slovensko
Slovinsko
Španělsko
Srbsko
Švédsko
Švýcarsko
Ukrajina
Vatikán
Velká Británie