Fire Resistant Cavity/Smoke Barrier
Fire Resistant Cavity/Smoke Barrier
    Promat

    Fire Resistant Cavity/Smoke Barrier

    The purpose of a cavity and smoke barriers is to prevent the spread of smoke and flame from penetrating and/or moving within a concealed space in a fire compartment. Documents supporting the regulations provide guidance on where such barriers should be located within hidden voids in a building and they usually give examples of deemed-to-satisfy barriers for voids in or above stud walls or partitions.

    If a barrier in a concealed space coincides with a compartment wall or floor it will normally be required to provide the same fire performance as the wall or floor. If the barrier is located between such compartment walls or floors however, the barrier is defined as a “cavity barrier” and will normally only be required to provide 30 minute integrity and 15 minute insulation (depending on local building regulations).

    A parapet is a low standing wall above a roof, on top of either an external wall or a fire separating wall. A parapet wall is supposed to prevent fire venting through the roof on one property and crossing over the separating wall down into any adjacent property.

    A spandrel panel is used generally as part of curtain walling systems. The spandrel panel generally protects vertically up from the top of a floor slab, or down from the underside of a floor slab. Spandrel panels are supposed to deflect fire and prevent spread of flames via the ends of floor slabs. A spandrel wall is designed to form a separator at any part of a window or an opening in an external wall above another opening in the storey below. The vertical construction projects no further than 450mm outside the lower opening.

    Parapet and spandrel walls should normally be approved in accordance with the criteria of BS 476: Part 22: 1987, which is required to satisfy a minimum fire resistance of 60/60/60 (for exceptions please check with local building regulations guidance documents or, if relevant, insurance codes).

    Technická specifikace
    • Jedinečná ref. hodnotacavity_barrier
    • Skupina výrobkůFire Products
    • Skupina produktůCavity and Smoke Barriers
    • TypSestavit (několik objektů)
    • Datum zveřejnění2021-06-09
    • Číslo vydání1
    • Výška (mm)2440
    • Šířka (mm)1220
    Související
    • Hlavní materiálKalcium silikát
    • Navrženo vHongkong
    • Vyrobeno vHongkong
    Klasifikace
    • Kategorie objektu BIMProtipožární produkty - Požární Bezpečnost
    • Klasifikace IFCObjekt
    • Kód ETIMEG000056
    • Název ETIMFire protection systems
    • Název UNSPSCFire protection
    • Kód UNSPSC4619

    Dostupnost regionu

    Asie Oceánie
    Arménie
    Americká Samoa
    Ázerbájdžán
    Austrálie
    Bangladéš
    Cookovy ostrovy
    Bhútán
    Federativní státy Mikronésie
    Britské indickoocenánské území
    Fidži
    Brunej
    Francouzská Polynésie
    Čína
    Guam
    Filipíny
    Kiribati
    Gruzie
    Marshallovy ostrovy
    Hongkong
    Nauru
    Indie
    Niue
    Indonésie
    Nová Kaledonie
    Japonsko
    Nový Zéland
    Kambodža
    ostrov Norfolk
    Kazachstán
    Palau
    Kokosové ostrovy
    Papua-Nová Guinea
    Korejská lidově demokratická republika
    Pitcairnovy ostrovy
    Korejská republika
    Šalamounovy ostrovy
    Kyrgyzstán
    Samoa
    Laos
    Severní Mariany
    Macao
    Tokelau
    Malajsie
    Tonga
    Maledivy
    Tuvalu
    Mongolsko
    United States Minor Outlying Islands
    Myanmar (Barma)
    Vanuatu
    Nepál
    Východní Timor
    Pákistán
    Wallis a Futuna
    Singapur
    Šrí Lanka
    Tádžikistán
    Tchaj-wan
    Thajsko
    Turkmenistán
    Uzbekistán
    Vánoční ostrov
    Vietnam